(4) Each time the 1HR. TIMER button is pressed,
the display changes as shown below.
Press this button 2 times to change the
display to “oP-7” (address setting).
(Fig. 64a or 64b)
(5) “oP-7” has now been selected for address
setting.
(6) Press the ON/OFF operation button on the
remote controller. (Fig. 64a or 64b) Check
that the “beep”signal-received sound is heard
from the second indoor unit (approximately
5 times). The sound you hear is the signal
that the remote controller address has been
changed.
(7) Finally press the remote controller ACL (Reset)
button to cancel the blinking “oP-7” display.
(Fig. 64a or 64b)
Changing of the second remote controller address
is now completed.
Selfdiagnostic mode
Test run mode
Address setting mode
Fig. 62
Fig. 63
Tab
ACL button
ION
button
ADDRESS
ACL (Reset)
button
ON/OFF
operation
button
1HR.TIMER
button
7. Address Switch
7-1. Address Setting of the Remote Control Unit
The address can be set in order to prevent interference between remote con-
trollers when 2 indoor units are installed near each other. The address is nor-
mally set to “A.” To set a different address, it is necessary to change the
address on the second remote controller.
Once changed, you cannot restore the original address setting of the air con-
ditioner.
(1) Switch on the power source.
(2) Break the address-setting tab marked “A” on the second remote controller
to change the address (Fig. 62). When the tab is removed, the address is
automatically set to B (Fig. 63).
(3) (SAP-KMRV74EH, KMRV94EH, KMRV124EH, KRV184EH, KRV244EH)
Press and hold the remote controller ION button and 1HR. TIMER button.
Then, press and hold the ACL (Reset) button with a pointed object such
as the tip of a pen. After 5 seconds, release the ACL button first, then
release the ION and 1HR. TIMER buttons. “oP-1” (Test Run) appears,
blinking in the remote controller clock display area.
NOTE
Fig. 64a
1HR.
TIMER
button
ON/OFF
operation
button
ACL
(Reset)
button
QUIET
button
Fig. 64b
(SAP-KMRV74, KMRV94, KMRV124,
KRV184, KRV244)
(SAP-KMRV76, KMRV96,
KMRV126, KRV96,
KRV186, KRV246)
23
(SAP-KMRV76EH, KMRV96EH, KMRV126EH, KRV96EHDS, KRV186EH, KRV246EH)
Press and hold the remote controller QUIET button and 1HR. TIMER button. Then, press and hold the ACL (Reset)
button with a pointed object such as the tip of a pen. After 5 seconds, release the ACL button first, then release the
QUIET and 1HR. TIMER buttons. “oP-1” (Test Run) appears, blinking in the remote controller clock display area.
08-080 CMRV3146EH_IU ENG 2/15/08 6:53 PM Page 23