Air Conditioner - Air Conditioner/Heater User Manual

42
10. FUNCTION
10-1. Room Temperature Control
Room temperature control is obtained by cycling the compressor ON and OFF.
Cooling
Thermo. ON : When the room temperature rises above T + 4°F (T°F is set temperature).
Compressor
ON
Thermo. OFF : When the room temperature falls below set temperature T°F.
Compressor
OFF
ON
ON
T °F
T+4 °F
set temp.
Compressor
Fan motor
Set speed
Room temp.
OFFOFF OFF
Cooling Only Model
Models STB0810C1 STB1010C1 STB1020C1 STB1220C1