INSTRUCTION MANUAL VACUUM CLEANER SC-X80 SC-X90 Contents IMPORTANT SAFETY INSTRUCTIONS 1 NAMES OF EACH PART 3 PREPARATIONS BEFORE USE 4 USING THE VACUUM CLEANER 6 USING THE ATTACHMENTS 7 EMPTYING THE DUST COMPARTMENT 8 CLEANING THE FILTERS 9 CLEANING THE SECONDARY FILTERS 10 CLEARING BLOCKAGES AND CLEANING THE AGITATOR ASSEMBLY 11 REPLACEMENT INSTRUCTIONS 12 TROUBLESHOOTING 15 15 REPLACEMENT PARTS HOUSEHOLD USE ONLY
IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following. READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER WARNING - To reduce the risk of fire, electric shock or injury: 1. Do not leave the vacuum cleaner when plugged in. Unplug it from the outlet when not in use and before servicing. 2. Do not use outdoors or on wet surfaces. 3. Do not allow it to be used as a toy.
16. Do not touch the agitator while it is spinning. 17. Do not place any heavy items on top of the vacuum cleaner. 18. Do not step on the hose or pull it too strongly. 19. Do not pick up items such as pieces of waste paper or cloth which look as though they may cause the hose to become blocked. 20. Do not clean or store the vacuum cleaner in places where there are high temperatures. 21. Store the vacuum cleaner away from excessive humidity. 22.
NAMES OF EACH PART FRONT REAR Handle Cord Storage Hooks Suction Hose Hose Holder Release Button Carrying Handle Dust Compartment ON/OFF Switch Power Cord Power Cord Plug Plug shown in figure may differ from actual plug attached to unit for your area. Crevice Tool Wand Filter Cover Upholstery Tool & Dusting Brush Handle Release Holder Mount Fork WARNING: Operate vacuum cleaner only at the voltage specified on name plate.
PREPARATIONS BEFORE USE Caution: Do not connect the power cord plug to the wall outlet until assembly is completed. Attaching the handle vacuum cleaner The handle screw has 1 toSetthetheupright 2 been position. installed for shipping purposes. Remove the screw before inserting handle. Insert the handle as shown in the illustration. the screw that you 3 Insert removed.Be sure screw is tightened,but not over tightened.
PREPARATIONS BEFORE USE WINDING THE POWER CORD Hook the power cord over 1 the clip which is located on Wind the power cord around the cord 2 storage hooks. the upper cord storage hook as shown. Cord Storage Hooks Plug Side Clip Hose Holder Plug shown in figure may differ from actual plug attached to unit for your area. Holder Mount RELEASING THE POWER CORD Rotate the upper cord storage hook 1 downward. Return the hook to the 2 upright position before attempting to rewind the power cord.
USING THE VACUUM CLEANER ON/OFF SWITCH Start or stop vacuum cleaner by pushing on the switch. OFF ON/OFF Switch ON ADJUSTING THE HANDLE The handle of this vacuum cleaner can be set to one of three positions-Upright,Normal,Parallel.Place your foot on either one of the handle release points as shown and pull back on the handle until it releases from its upright position.
USING THE ATTACHMENTS Caution: When using the attachments during cleaning, set the vacuum cleaner to the upright position. 1 2 Disconnect the hose from the vacuum cleaner. Hose Pull the hose gently in the direction of the arrow to disconnect it. Hook the hose holder onto the holder mount. Caution: Before using the attachments, please make sure the hose is hooked on the holder mount. Hose Holder 2 3 Remove the wands from the vacuum cleaner. Holder Mount 1 Two wands are contained together.
EMPTYING THE DUST COMPARTMENT Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect the power cord from the wall outlet before cleaning. 1 Empty the dust compartment when contents reach the MAX mark. 2 Push the release button to remove the dust compartment. Release Button MAX mark 3 Press the release lever to open the trapdoor. Turn the duster handle several times in the 4 direction shown to empty the dust compartment.
CLEANING THE FILTERS 1 Remove the dust compartment.(refer to page 8) the dust compartment to the 2 Set parallel position. Open the trapdoor, Release Button B then push the release button B and pull out the main filter. The main filter and prefilter will be removed at the same time. Caution: Do not push the release button B at the upright position. As this may drop or damage the main filter and prefilter. 3 the main filter and prefilter with a soft-bristled brush and rinse with cold water.
CLEANING THE SECONDARY FILTERS Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect the power cord from the wall outlet before cleaning the filters. CLEANING THE AIR OUTLET FILTER The secondary filters consist of a general filter and a sub-filter. Only use genuine Sanyo replacement filters. 1 2 Remove the filter cover. 3 Gently clean the air outlet filter with water. 4 Make sure that it is completely dry and then re-install it into the filter cover.
CLEARING BLOCKAGES IN THE SUCTION HOSE AND CLEANING THE AGITATOR ASSEMBLY Caution: Be sure to turn the ON/OFF switch to the" OFF " position and disconnect the power cord from the wall outlet before clearing any blockages in the suction hose and cleaning the agitator assembly. Clearing blockages in the suction hose 1 Set the vacuum cleaner to the upright position. Remove the hose cuff from the suction inlet and 2 then remove any blockages from the hose.
REPLACEMENT INSTRUCTIONS Caution: Be sure to turn the ON/OFF switch to the "OFF " position and disconnect the power cord from the wall outlet before replacing any of the parts below. REPLACING THE FLAT BELT 1 2 Remove the bottom plate. (refer to page 14) Lift out the agitator assembly,and then remove the flat belt from the motor shaft and the agitator pulley. Motor Shaft Flat Belt Agitator Assembly 3 Place a new flat belt onto the motor shaft and pulley.
REPLACEMENT INSTRUCTIONS Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect the power cord from the wall outlet before replacing any of the parts below. REPLACING THE AGITATOR 1 2 Remove the bottom plate. (refer to page 14) Lift out the agitator assembly,and then remove the agitator assembly as shown. Motor Shaft Flat Belt Agitator Assembly 3 Place the flat belt onto the pulley of the new agitator assembly.
REPLACEMENT INSTRUCTIONS REMOVING THE BOTTOM PLATE the vacuum cleaner to the 1 Set parallel position and turn it over. Pull here Latch 2 PULL Slide the latch in the direction shown. Bottom Plate the bottom plate by pulling 3 Remove the tabs as illustrated. REATTACHING THE BOTTOM PLATE the projection on the 1 Insert bottom place into the groove plate as shown. 2 Push the bottom Press Press on the nozzle head and set the bottom plate in place.
TROUBLESHOOTING If there is a problem with the vacuum cleaner, carry out the following checks to find the cause. If the problem still persists after the checks have been made, do not use the vacuum cleaner to prevent the possibility of an accident occurring. Turn the ON/OFF switch to the "OFF" position, disconnect the power cord from the wall outlet, and contact the place of purchase or your nearest Sanyo Service Center.