Installation Manual V3 SMA 2000 Series Master Clock The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Wall Mount Installation Fig 1 1. Remove the cover of the wiring panel (Fig 1). 2. Mark the four drilling points on the wall based on the drawing above. 3. Drill the holes for the anchors supplied in the mounting kit at the designated markings from step 1. 4. Install the four anchors in the holes that were just drilled. 5.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Rack Mount Installation 1. The master clock is 1U in size. Install the threaded nuts in the desired location in the rack rails. 2. Put the nylon washers on the two screws supplied. 3. Line up the master clock with the threaded nut. 4. Insert screws into the threaded nuts and tighten.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Before You Get Started Installing the Master Clock with the Line Cord Receptacle Remainder of cord not shown Caution! Do not plug in the power cord until the following steps are completed. 1. The square knockout on the wiring chassis must be removed. 2. The Heyco Bushing must be attached to the power cord as shown.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Rear View of Unit | | q | | | | w | | e r | | t | | y | | | | u i | | o q w e N/A r RS485 Input/Output This terminal block is where connections would be landed for RS485 communication to and from other Sapling systems. t Inputs This terminal block is where connections would be landed to use the SMA as a slave clock when being controlled by another system.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Remote Antenna Mounting Instructions 1. 2. 3. 4. 5. 6. 7. 8. Remove the cover of the wiring panel. Mark the four drilling points on the wall based on the drawing above. Drill the holes for the anchors supplied in the mounting kit at the designated markings from step 1. Install the four anchors in the holes that were just drilled.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Inputs – Sync-Wire Inputs Installation 59 Minute Correction 12 16 N.O. 17 15 17 24VAC Hot 8 24VAC Interface 24VAC Neutral 17 110VAC Neutral 7 110VAC Interface 110VAC Hot Dry Contact Closure COM 58 Minute Corrections 1–4 N.O.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Fire Alarm Interface Installation / Patch Cable Installation Fire Alarm Interface Installation The Fire Alarm Interface allows a relay closure to be connected to the SMA master clock that allows the user to interface the existing fire alarm with the Sapling SBD 1000 or SBD 2000 series digital clocks. 7 10 8 9 N.O.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com User Level Programming Setting the Time from the LED Display To set the time, press the top button to change the hour and/or the bottom button the set the minute. See Fig 2.1. Fig 2.1 Programming the SMA 2000 To enter programming mode, press both the top and bottom button together simultaneously.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com User Level Programming Option 3 - Set Day: Use the bottom button to scroll between “01-31”. Option 10 - Technical Mode: If technical mode is desired, press the bottom button until “08” is reached. Setting option 10 to “08” will allow the user access to options 11-13 when the top button is pressed. Any other value will go directly to option “20” when the top button is pressed.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com User Level Programming Option 20 - Programming the Clock #1 Circuit: Press the bottom button to scroll through “1”, “2”, “3”, “4”, “5”, “6”, “7”, “8” & “9”. Please refer to relay selection mode on page 21. Option 21 - Once a Day Pulse - Set Hour: This option is only available if “8” is selected in option 20 for once a day pulse. Press the bottom button to scroll through “00-23”.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com User Level Programming Option 25 - Programming the Clock #2 Circuit: Press the bottom button to scroll through “1”, “2”, “3”, “4”, “5”, “6”, “7”, “8” & “9”. Please refer to relay selection mode on page 21. Option 26 - Once a Day Pulse - Set Hour: This option is only available if “8” is selected in option 25 for once a day pulse. Press the bottom button to scroll through “00-23”.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com User Level Programming Option 30 - Set the Primary Input: Press the bottom button to scroll between “1-13” to select the input.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com User Level Programming Option 35 - Once a Day Pulse Input - Set Minutes This option is only available when option 30 or 31 is set to 11. Press the bottom button to scroll through “00-59”. Option 36 - Once a Day Pulse - Set Seconds This option is only avaiable when option 30 or 31 is set to 11. Press the bottom button to scroll through “00-59”.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com User Level Programming Option 50 - Entering Diagnostic Mode Press the bottom button to scroll between “E - d”. Setting the option to “E” will enable the option and will enter diagnostic mode. Setting the option to “d” will disable the option and upon depressing the top button, the clock will return to the time.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com System Connections – Wired Systems Sync-Wire Communication – Protocol Definitions 58th minute (1) The hourly correction for 55 seconds every hour from XX:58:05 to XX:59:00. The daily correction (5 a.m. & 5 p.m.) is ten correction cycles sent to the relay (each for 95 seconds) beginning at 5:05:00, 5:07:00, 5:09:00, 5:11:00, 5:13:00, 5:15:00, 5:17:00, 5:19:00, 5:21:00, and 5:23:00.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Interface Programming The web interface is an optional feature and is not available on all units. Please make sure that ports 123 and 80 are open on the firewall. Accessing the Web Interface (when connected via DHCP) 1) Plug in a patch cable to the unit, and then into a switch on your network.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming Log In q w e q Password There are two levels of passwords that will enable the user to access features. The first level is the user level programming that includes features like setting the time, date, adding and editing events and schedule changes. The default password for the user level is 1111. It can be changed in the technician level.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming Main Menu q w e r t q Technician Menu This link will access the Technician Menu log-in page. The Technician Menu is password protected and has access to system settings, IP settings, as well as feature settings for the master clock. w Time This field is where the current time is displayed.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming Technician Level Menu q w e r t y u i q System Settings This link, when clicked, will enter the System Settings pages. These pages include the user password, the RS485 data rate, setting the offset, the input selection, setting Clock #1 and Clock #2 sync-wire protocol outputs and resetting the unit back to manufacturer’s default settings.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming System Settings Page 1 q w e r t y i q w e User Password r GMT Offset This field sets the positive or negative offset for GMT time. For instance, eastern time zone is a negative five hour offset. See Fig 4.1 for typical offsets. This field allows the user to enter a new password for the user level programming. The default is 1111.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming System Settings Page 2 q w e r t y u i q Input Selection This drop-down list allows the user to select which input will control the master clock.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming IP Settings Page 1 q w e r t y u i o q w e r Gateway IP Address t DHCP This drop down list allows the user to turn DHCP on or off. DHCP allows the master clock to look for an IP address on its own if the network has a DHCP server.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming IP Settings Page 2 q w e r t y q Retry Failed-Server After moves on to the next one. w Server Addresses This field allows the user to specify which NTP servers that the master clock will try to acquire time from. Any server that is highlighted in red is not functioning after several tries.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming IP Settings Page 3 q w e r t y u q w e r t y u MAC Address IP Address This displays the MAC address for the master clock. This display the IP address for the master clock. Processor Serial Number Software Build Date Device Name This displays the date the unit was built. This displays the device name for the master clock.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming Clock Features q w e r t q Display Format LED. w Daylight Savings Time This drop-down list allows the user to select which daylight savings time option they want. The option can be disabled, pre-2007 and post-2007. Pre-2007 has the old-style daylight savings time format that was enacted prior to 2007.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Web Browser Programming Database Maintenance q w e r q w e Upload Database r Menu Choose File This button, when pressed, will upload the current schedules and events, and place it in a file for backup purposes. This button, when pressed, will allow the user to browse for the saved .db file that contains the saved events and schedules.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Support Frequently Asked Questions Does this master clock replace all of the existing master clocks made by Sapling? The SMA Series will act as a direct replacement for the GPS, STR and SSM series master clocks. The SMA can have all the same functionalities of the aforementioned series depending on which options are ordered.
The Sapling Company, Inc. 1633 Republic Road Huntingdon Valley, PA 19006 215.322.6063 P. 215.322.8498 F. www.sapling-inc.com Support Troubleshooting The master clock will not power up. What do I do? Make sure the power cord is securely connected to the power outlet and to the back of the SMA master clock. Upon being connected to power, the master clock should boot up instantly. There is not an on/off switch.