Brochure
6
23
⁄32” (171 mm)
Left View
Front View
23
1
⁄4” (590 mm)*
20
11
⁄16” (526 mm)
14
7
⁄8” (377 mm)
32” to 33” (812 to 838 mm)
32” to 33” (812 to 838 mm)
18
5
⁄8” (472 mm)
28” (712 mm)
*Dimensions are the same for Panel Ready unit when
3
⁄4” panel applied
24.00”
(610 mm)
15.00”
(381 mm)
6.00”
(152 mm)
11.00”
(280 mm)
Electrical hook-up
location
Cut-out Dimensions with Electrical
Water Line and Drain locations
Recommended location for water line, drain line and
electrical connection is in either adjacent cabinet
SAPPHIRE
CONFIDENTIAL
15” ADA Ice Machine
9/30/20
Cut out graphics
Widths:
Ice: (including water line)
15” ADA
15” Standard
Refer
Standard
15”
24”
ADA
24”
Heights:
ADA Cutout. 32-33
Standard: 34-35
The electrical/ Inlet Water location is OK, if installing directly behind the unit or putting in adjacent cabinetry.
For non pump the height of 6.75”(172mm=89/2+127mm) For 15” ice maker is OK. It is correct to illustrate the ¼”
drop for every foot of drain line.
For drain pump models, in case of air column remaining in the pipe, the height of drain hole location should be
equal or higher than 9.8”(248mm) to ensure the drain pump running smoothly . The drain pump head is 1.5m, so
the max height of the drain pipe that the pump operates properly is 1.5m. The length of drain pipe is 10 feet(3m),
the distance of the drain pipe on left or right side should be about 9’. Please refer to the red cloud shape below for
the Details.
NOTE:
For Gravity drain models, the drain hole cannot exceed 7 inches
above the floor. For Pump models, the drain hole should be no
lower than 7 inches and no higher than 4 feet above the floor.
32.00”
(813 mm)
to
33.00”
(838 mm)
NOTE: For Gravity drain models, the drain hole cannot exceed 7 inches above the oor.
For Pump models, the drain hole should be no lower than 7 inches and no higher than 4 feet above the
oor.
24” (610 mm)
11” (280 mm)
32” (812 mm)
to
33” (838 mm)
Electrical hook-up
locaon
7” (177 mm)
15” (381 mm)
Recommended locaon
for water line, drain line
and electrical connecon
is in adjacent cabinet
24.00”
(610 mm)
15.00”
(381 mm)
34.00”
(867 mm)
to
35.00”
(889 mm)
6.00”
(152 mm)
11.00”
(280 mm)
Electrical hook-up
location
Cut-out Dimensions with Electrical
locations
SAPPHIRE
CONFIDENTIAL
15” Refrigerator
9/8/20
Back View
1
7
⁄8” (47 mm)
3” (75 mm)
Drain Line
Water Inlet
Water Inlet
Power Cord
Drain Line (10 )
3
⁄4” (19 mm)
8
29
⁄32” (266 mm)
5
7
⁄16” (138 mm)
Power Cord (6 )
Cube SizeCube Size
All specicaons are subject to change without noce.
Control Type Electronic Capacitave Touch with OLED Screen
Indoor or Outdoor Indoor
Built-in Installaon Inset, Frameless / Overlay and Framed Cabinet Styles
Ice Size
7
⁄8" x
7
⁄8" x
7
⁄8"
Ice Weight (g) per unit 11 g / 0.024 lbs
Ice Quanty per cycle 40 per Slab (1 lb)
Ice Producon Capacity 75 lbs
Ice Storage Capacity 25 lbs
Refrigerant Type R290
Electrical Requirements 115 V / 60 Hz
Volt Range 104 V ~ 127 V
Electrical Service 15 amp
Running Amps 1.9 amps
Water Inlet Adapter
1
⁄4" OD Compression Fing*
Water Pressure Operang Range (psi) 20 psi – 80 psi
Water Usage
12
1
⁄2 gallons per 100 lbs of ice
Factory Installed Drain Line 10 feet
Drain Required Yes (See manual for details)
*Water line not included
ADA Height Compliant Yes
Energy Star Yes
ETL Sanitaon Yes
UL Commercial Yes
SapphireAppliances.com