Specifications

page 9
V. Management/Employee Access
During everyday operation of the lock, the Manager or Supervisor ‘enables’ the lock, and the lock can then
be opened by User Codes until it is “disabled”. There are two versions of the enable/disable function:
• In the first version, only the Master and the Supervisor can both enable and disable the lock.
• In the second version, Users may disable the lock (Master and Supervisor can still disable the lock).
a. Program the Lock for Enable/Disable Operations as follows:
3 2 * Master Code #

2 #

2 #

After this step, the lock is in the disabled mode.
b. To enable all codes (Users, Master and Supervisor):
5 5 * Master or Supervisor Code #

After this enabling command, Master, Supervisor or User codes can open the lock.
c. To disable all codes:
5 5 * Master or Supervisor Code #

No code can open the lock. Entry of any code results in the lock beeping 2 low tone beeps
indicating the lock is disabled.
d. Program the lock for a “special” user disable function with the following command:
5 6 * Master Code #

1 #

1 #

e. After the lock is enabled by the Master or Supervisor code, any User code can disable lock by entering:
5 5 * User Code #

Note: Master and Supervisor Codes can also disable the lock in the User Disable version.
f. To turn off the “special” user disable function:
5 6 * Master Code #

0 #

0 #

Now only the Master or Supervisor Code can disable the lock.
g. To program the lock out of the enable/disable mode:
3 2 * Master Code #

1 #

1 #
