Keypad Programming Instructions © SARGENT Manufacturing Company for the Profile Series LK and v.G1 Locks A7716B www.sargentlock.
Table of Contents Page 1 LK Programming .......................................................1-4 2 Transaction Log for LK ..................................................4 3 G1-LU, G1-PA, G1-PK, G1-TU, G1-TA, G1-TP Programming....5-8 4 G1-PA and G1-TA Programming........................................8 5 Chain Programming......................................................9 6 Log Sheet for Keypad Programming ......................
Keypad Programming Instructions for the Profile Series LK and v. G1 Locks The Keypad Lock can support 100 (LK) / 2000 (G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA) users. Each user is assigned a User Number in addition to the code used for entry. Example for v.
Keypad Programming Instructions for the Profile Series LK Lock To Enter the Emergency Code 99# Master Code* Yellow LED blinks 50# 02# Yellow LED blinks Emergency (1-6 digits)* Yellow LED blinks quickly Emergency (1-6 digits)* Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out Emergency Code defaults to a 10 second unlock time and will override a thrown deadbolt on a mortise lock.
Keypad Programming Instructions for the Profile Series LK Lock To Program Door Name into Keypad 99# Master Code* 43# Door Name (up to 5 digits)# 0# * * Yellow Yellow Yellow Yellow Yellow LED LED LED LED LED blinks blinks blinks quickly blinks slowly (If solid, see note) goes out Yellow Yellow Yellow Yellow LED LED LED LED blinks blinks blinks quickly goes out (If solid, see note) To Interrogate Transaction Log 99# Supervisory or Master Code* 70# 0# 0# * * Hold an infrared printer up to the infrared
Keypad Programming Instructions for the Profile Series LK Lock To Set Unlock Time 99# Master Code* Yellow LED blinks 11# (1-99 sec)# 0# Yellow LED blinks * Yellow LED blinks quickly * Yellow LED blinks slowly (If solid, see note) * Yellow LED goes out The Unlock Time is adjustable for Momentary Operation. A 5 second unlock time is recommended to extend battery life. Once the unlock time is entered, it is the same for ALL users except 02.
Keypad Programming Instructions for the Profile Series v. G1 Lock 3 G1-LU, G1-PK, G1-TU and G1-TP Programming (2000 Users) To determine programming steps for your lock: + + + - + + + - LU PK If your label has a G1-LU, G1-PK, G1-PA, G1-TU, G1-TP, G1-TA, then use the programming below. If your label has an LK, turn to LK programming in Section 1.
Keypad Programming Instructions for the Profile Series v. G1 Lock Enter a Lock Out User Code 99# Master Code* 50# 3# (User Location 04-2000)# User Code* User Code* * Note: The "lock out" user is location dependent. To program this user at "user location" #4.
Keypad Programming Instructions for the Profile Series v.
Keypad Programming Instructions for the Profile Series v. G1 Lock Status Indicators 3 very rapid beeps after User Code entered - Invalid User Code 4 long beeps after User Code entered - Low Battery Indication 4 long beeps after User Code entered, 4 more long beeps - Voltage too low to operate.
Keypad Programming Instructions for the Profile Series v. G1 Lock 5 Chain Programming When programming multiple User Numbers and Codes into the LK, G1-LU, G1-PK, G1-TU and G1 TP Lock, it is not necessary to leave and re-enter the programming Mode (50) for each entry. Multiple entries may be chained together and the three different types of user codes (Standard, Passage and One Time) may be mixed.
Keypad Programming Instructions for the Profile Series v. G1 Lock Supplemental – Individual “Door” Log Sheet for keypad programming 6 Lock Model: Door Name: Location: Function Master Code Supervisory Code Table 1: Main Codes - User Programmed “Door” Log User Number Default Code User Programmed Code 01 1234* 02 *Note: If memory is cleared, you must reprogram Emergency code. The Master code resets back to 1234*.