Full-Teflon Paddle and Shaft (one piece
mould); numbered, certificate of compliance
MagniShaft 89-000-7001
UniShaft 89-010-7001
Full-Teflon Basket holder and Shafts; num-
bered
UniShaft 84-010-6011
MagniShaft 89-000-6001
St. Steel 84-010-6012
Full-Teflon Basket holder and Shaft; num-
bered with certificate of compliance
UniShaft 89-010-6001
MagniShaft 89-000-6001
Basket, mesh 40 90-000-6040
Basket, mesh 40, numbered with certificate
of compliance 95-000-6040
Basket, mesh 20 90-000-6020
Basket, mesh 20, numbered with certificate
of compliance 95-000-6020
Basket, mesh 10 90-000-6010
Other methods (USP 5, 6 etc.) and Vessel for
other media volume on request
3. Video Monitoring/Recording
Video Monitoring/Recording of Dissolution
Tester 1 (6 stations). Recording of the disso-
lution process and time laps view with real-
time dissolution curve overlay (only in com-
bination with UV-VIS Online analysis)
72-210-1xxx
Video Monitoring/Recording of Dissolution
Tester 2 (6 stations).Recording of the disso-
lution process and time laps view with real-
time dissolution curve overlay (only in com-
bination with UV-VIS Online analysis)
72-210-2xxx
Upgrade Software for Video Monitor-
ing/Recording tool (in case both testers are
equipped with Video Monitoring/Recording
the upgrade software is only required once).
50-050-0000
4. Filtration
The kind of filtration required depends on the
product to test
Tip Filtration by Poroplast filters (from 1 µm)
attached to the sampling tube of the Sam-
pling System comes as standard
Double Filtration System combination of a tip
filter (see above) and one membrane filter
(typically from 0.45 µm) integrated in the
flow of the withdrawn sample. For filtration
below 1.0 µm Media Transfer Pump PVP
820 is recommended! 80-070-0955
Automatic Filter Changer, Type AFC 825
Unit for exchange of the membrane filters af-
ter each sampling interval (selectable) with
storage capacity for 8x 25 membrane filters.
Media replacement only available in combi-
nation with filter exchange.
12-085-0825
5. Sample Transfer Pump
Sample Transfer Pump, Peristaltic 8-channel
Ismatec Peristaltic Pump incl. Verderprene
tubing. Usage depends (usually not below
1µm) on filter and product to be used.
11-202-5000
Sample Transfer Pump, Piston (high pres-
sure) 8-channel ERWEKA valve-free Tef-
lon/Ceramics Piston Pump. Dependant on
the product this pump allows filtration down
to 0.22µm due to the high pressure created.
High dosage accuracy. 10-312-1201
6. Half-automated HPLC- and
UV-VIS Online, HADs
HADs Base Module
HADs for HPLC Online analysis, incl. block
of sealed PEEK flow-through vials, rack for
up to 5 standards for calibration and system
suitability, needle/syringe wash-station, me-
dia replacement, sample handling system, 1-
channel syringe pump, 6-port HPLC valve
and system tubing/pre configuration; for
connection of 1 Dissolution Tester; for con-
nection of 1 HPLC system with software
(Agilent, Waters, Shimadzu, Merck/Hitachi
etc.) Price excluding sample transfer pump,
sample collection rack, software and HPLC-
and UV-VIS unit! 72-210-0001-4