EM132-133 QUICK START GUIDE Quick Start Guide EM132-133 BG0504 REV.
EM132-133 QUICK START GUIDE Mechanical Installation Figure 1: Instrument Dimensions 2 BG0504 REV.
EM132-133 QUICK START GUIDE Mechanical Installation Figure 2: Mounting the EM133 on DIN Rail or on flat surface IMPORTANT! Only qualified personnel can perform setup. All incoming power sources must be turned off during installation. During operation of the Powermeter, hazardous voltages are present on the input terminals. Failure to observe precautions can result in serious or even fatal injury, or damage to equipment. Please refer to the installation and operation manual for further information.
EM132-133 QUICK START GUIDE Typical Electrical Installation Figure 3:Common Wiring Mode: 4LL3 or 4Ln3 Wiring Configuration 3-wire 2-element Direct connection using 2 CTs 4-wire Wye 3-element direct connection using 3 CTs 4-wire Wye 3-element connection using 3 PTs, 3 CTs 3-wire 2-element Open Delta connection using 2 PTs, 2 CTs 4-wire Wye 2½ -element connection using 2 PTs, 3 CTs 3-wire 2½ -element Open Delta connection using 2 PTs, 3 CTs 4-wire 3-element Delta direct connection using 3 CTs 3-wire 2½-ele
EM132-133 QUICK START GUIDE Electrical Installation Figure 4: CT Wiring options BG0504 REV.
EM132-133 QUICK START GUIDE MODULE Installation This section applies to the I/O and Communication modules.
EM132-133 QUICK START GUIDE Basic Setup All setups can be performed directly from the display panel or via communication ports using PAS communication software, except for Communications and Display setups, which must be performed directly at the instrument panel.
EM132-133 QUICK START GUIDE DATA DISPLAY Navigating in Display Mode The front panel has a simple interface that allows you to display numerous measurement parameters in up to 38 display pages. For easier reading, the parameters are divided into three groups; each group is accessible by pressing the key and each group page is accessible by pressing the key. The initial display is as described below: First push on will display Energy measurement parameters, by pushing exp.
EM132-133 QUICK START GUIDE Basic Menu Code Parameter ConF Wiring mode Pt Ratio Pt Factor PT ratio Ct CT primary current Options Description 3OP2 3-wire open delta using 2 CTs 4Ln3 4-wire Wye using 3 PTs (default) 3dir2 3-wire direct connection using 2 CTs 4LL3 4-wire Wye using 3 PTs 3OP3 3-wire open delta using 3 CTs 3Ln3 4-wire Wye using 2 PTs 3LL3 4-wire Wye using 2 PTs 3bLn3 3-wire Broken delta using 2 PTs, 3 CTs 3bLL3 3-wire Broken delta using 2 PTs, 3 CTs 1.0 - 6,500.
EM132-133 QUICK START GUIDE Input and Output Ratings /5A(10A) DIRECT INPUT - Nominal: 690V line-to-line voltage, 828V maximum; 400V line-to-neutral, 480V maximum - Burden: <0.5 VA. INPUT USING PT - Burden: <0.15 VA 4 x Maximum wire section: 2.5 mm² (12 AWG) INPUT VIA CT with 5A secondary output - Burden: <0.2VA, Overload withstands: 20A RMS continuous, 300A RMS for 0.5 second. /1A(2A) INPUT VIA CT with 1A secondary output - Burden: <0.05VA, Overload withstands: 3A RMS continuous, 80A RMS for 0.