Firmware Version 1.12 Alarm Control Panels PROGRAMMING SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.
Before you start programming, please read carefully this manual in order to avoid mistakes that can lead to malfunction or even damage to the equipment. The SATEL's goal is to continually upgrade the quality of its products, which may result in alterations of their technical specifications and firmware. The current information on the introduced modifications is available on our website. Please visit us at: http://www.satel.eu The declaration of conformity may be consulted at www.satel.
Changes made to the firmware version 1.12 Service mode Option to hide the service mode using the HIDE SM NOW function. Zones New zone type: OUTPUTS GROUP ON. New option: DELAY IN 2&3 TYPE ARMING. System options The RETURN TO MENU FROM MENU "TEST" option applies also to the functions available in the CHANGE OPTIONS submenu. With the GRADE 3 option enabled, the PRIORITY option will be enabled for 9. 24H TAMPER type zones.
2 Programming SATEL CONTENTS 1. 2. General .............................................................................................................................4 Programming options........................................................................................................4 2.1 Keypad ......................................................................................................................4 2.1.1 2.1.2 2.1.3 2.1.4 2.1.5 2.1.6 2.2 DLOADX program..........................
SATEL INTEGRA Plus 5.2.1 5.2.2 3 Printout options ............................................................................................................ 57 Printout contents .......................................................................................................... 57 5.3 Other options ........................................................................................................... 58 5.4 Arming options......................................................................
4 Programming SATEL 1. General This manual applies to the control panels of the INTEGRA Plus series: – INTEGRA 64 Plus – INTEGRA 128 Plus – INTEGRA 256 Plus 2.
SATEL 2.1.2 INTEGRA Plus 5 Starting the service mode "from pins" When entering the service mode in the normal way is not possible (the control panel does not support LCD keypads, does not accept the service code, etc.), you can use the emergency procedure, so-called, starting "from pins." 1. Turn off the control panel power supply (first disconnect the AC power, and then the battery). 2. Put a jumper on the RESET pins located on the control panel mainboard. 3.
6 Programming GuardX ident. DloadX tel. No GuardX tel. No Block SM Block DWNL SM sounds Hide SM now Hide SM after Structure System Objects Edit object New object Delete object Partitions Settings [select partition by name] Type Dep. partitions Timers 1..32 Timers 33..64 Options 2 cds to arm 2 cds to d-arm Codes on 2 arm 1st code 30s Timer priority Fin. exit time Infin.ex.time Def.block time Al.-can disarm Exit delay Auto-arm delay Al. verify time Bell on 2nd Guard – armed Guard – disarm. Time for guard.
SATEL INTEGRA Plus Settings [select device by name – see: p. 16] ABAX confirmat. INT-IT-wt.2cd. Rem. RX key fobs Copy RX keyfobs Rem. ABAX kfobs Copy ABAX kfobs Names [select device by type and address] DT1 short Tmp.alw.ld.DT1 DT2 short Tmp.alw.ld.DT2 Identification LCD keypads id. Expanders id. Keypads addr. EOL R1 resistor EOL R2 resistor EOL R2 resistor Options Tel. options. Mon. TELEPHONE Mon.GPRS Mon. ETHM-1 Messaging SMS messaging Modem answer. Ext.mod.answ. Voice answer.
8 Programming Bypasses Access control Troubles User functions System events Active rights Various options Grade3 Simple codes Notify of code Confirm with 1 Autoabort msg. SM -> menu Tests -> menu No AC-no blght Fast exp. bus No rest. mon. Inf. aft. tamper Arm, view viol Arm, warn.trb. Blk aft.w.code Troubl. memory Hide alarms Events limit. View clear.al. L.no ABAX=tamp Do not arm If verif. al. If tamper If monit. trbl. If batt. trbl. If outs. trbl. If other trbl.
SATEL INTEGRA Plus PING tries Integrate key Zones Details [select zone by name] EOL Sensitivity [x20ms] / Pulses time / Sensitiv. [ms] / Output Pulses count Type Entry delay / Alarm delay / Surveillan. time / Signal. delay / Bypass time / Expander number / Arming mode / Group / Exit time / Outputs group Max.viol.time / Max.opening t. Max.n-viol.time No viol [min] Partition Power up delay Priority / Disrm.on viol. Chime in exp. / No al. in kpds. Video, disarmed Video, armed Bypass disabl.
10 Programming SATEL Zones Bypass on/off Test SIGNAL. OUTPUT [select zone] Names [select zone by number] Outputs Details [select output by name] Function Cut-off time Polarization + Pulsating Latch Timers control Timers 33..64 Arm - no ctrl. Off-delay tmr. Zones / Timers / Expanders / Outputs / Users / Doors / Voice mess. / Tel. switches (triggering) LCD keypads / Master users / Arm mode sel. / Dialing mode (triggering) Partitions / Burg.tst.part. (triggering) Fire.tst.part.
SATEL INTEGRA Plus [select schedule by name] Names [select schedule by number] Monitoring Mon. TELEPHONE Mon. GPRS Mon. ETHM-1 Dont rep. rsts. Stations Advanced Long hsk.s1t1 Long hsk.s1t2 Long hsk.s2t1 Long hsk.s2t2 Long hsk. wait. Need ack.id.s1 Id. 6-chars s1 Source name s1 Partit.name s1 SIA evr.bl.s1A / TELIM 0ton s1A SIA evr.bl.s1B / TELIM 0ton s1B Need ack.id.s2 Id. 6-chars s2 Source name s2 Partit.name s2 SIA evr.bl.s2A / TELIM 0ton s2A SIA evr.bl.s2B / TELIM 0ton s2B Station 1 Tel. 1 number Tel.
12 Programming Tel. 1 format Tel. 2 format IP address Port Key (MS) Key (GPRS) Key (ETHM) UDP SIA-IP MAC Coded Key (SIA-IP) Timestamp SIA-IP test Repetition cnt. Suspension time TELIM/SIA prefix Identifier n [n – identifier number] Identifier sys. Event assign. Id.
SATEL Tel. settings [select telephone by name] Tel.
14 Programming SATEL [select message] Pager types [select pager] Msg.abort in P. [select telephone by name] Msg.abort on T. [select telephone by name] SMS messaging SMS messaging Tel. names [select telephone by number] Tel. settings [select telephone by name] Tel.answ./ctrl. Voice answer. Double call Rings count On armed part. Remote control Users (all) [select user from the list of all users] Users (t.
SATEL Chime bps. zone Chime bps. time Quickarm part. Fin.exit time Entry time p. Exit time p. DateTime format Name (2nd row) LCD backlight Keys backlight Auto backlight Alarm messages Part. al.mess. Zone al.mess. Code + card Alarms Fire alarm Medical alarm Panic alarm Silent panic 3 wrong codes Options Entry time s. Exit time sig. Alarm signal. New trbl.sign. Key sounds Trbl.in p.arm. Zone violation Auto-arm delay Unkn. card sig. Ev.3 unk. cards Al.3 unk. cards Dspl. mode chg. Show code ent.
16 Programming Card close long Door to open Tamper in part. Z1 (n) in LCD Z2 (n) in LCD CA-64 PTSA Zones Partitions Alarms Show AC loss delay RS communicat. Tamper in part. ETHM-1 DHCP IP address Netmask Gateway DHCP-DNS DNS Port (WWW) Port (DloadX) Port (others) Port (integr.) Key (DloadX) Key (others) Connect DloadX Connect GuardX Connect Intern. Connect GSM PING test Integrate Coded integr. Tamper in part. Fail. – event Fail. – alarm INT-RS / INT-RS Plus DSR control RX control Tamper in part.
SATEL Entry time Exit time Auto-arm delay Hardw. signal Force arm Al. 3 unk .cards No autorst.3t. Tamper in part. INT-S / INT-SK / INT-SCR Lock feature Lock Lock function Relay ON time Relay type Unauth. event Unauth. alarm Max. door open Dependent door1 Dependent door2 Doors on fire Master users Users Code + card Code + card Code or card Follow output [n] Alarms Fire alarm Medical alarm Panic alarm Silent panic 3 wrong codes Options Quick arm Fin.exit time BI outs ctrl. MONO outs ctr. Part.
18 Auto backlight No autorst.3t. Partition INT-SZ / INT-SZK Lock Lock function Relay ON time Relay type Unauth. event Unauth. alarm Max. door open Dependent door1 Dependent door2 Doors on fire Master users Users Alarms Fire alarm Medical alarm Panic alarm Silent panic 3 wrong codes Options BI outs ctrl. MONO outs ctr. Part.blocking Guard control Changing code Signaling Code entered Chime zones Confirmation Backlight Auto backlight No autorst.3t.
SATEL INTEGRA Plus Lock Lock function Relay ON time Unauth. event Unauth. alarm Max. door open Dependent door1 Dependent door2 Doors on fire Master users Users Readers Reader A (does not apply to CA-64 DR) Reader A sound Reader A LED Reader A arms Reader B (does not apply to CA-64 DR) Reader B sound Reader B LED Reader B arms Al. rdrs tamper (does not apply to CA-64 DR) Hardw. signal. 3 wrong codes BI outs ctrl. MONO outs ctr. Part. blocking Guard control Code* not dis. Code* in arm C.
20 Programming Filter [select zone to which wireless device is assigned] Remove device [select zone to which wireless device is assigned] Synchronization Test mode on Test mode off CA-64 E / CA-64 O / INT-ORS / INT-IORS / CA-64 SM No autorst.3t. Tamper in part. CA-64 Ei (v. 2.00/2.01) No autorst.3t. Tamper in part. EOL Rp resistor CA-64 Ei (v. 4.00) No autorst.3t. Tamper in part. EOL R1 resistor EOL R2 resistor CA-64 EPS / CA-64 ADR / CA-64 OPS / CA-64 PP No autorst.3t. Tamper in part.
SATEL INTEGRA Plus 21 Microphone n [n = microphone number (1...4)] Speaker n [n = speaker number (1...4)] Only listen AVT buttons Sound signal. Silent alarm Satel commands Wait aft.event Wait aft.disc. Runtime No autorst.3t. Tamper in part. 2.1.6 Entering data by means of the keypad Data are saved to the control panel if you press the key (in some keypads, the key is also available, whose function is exactly the same). The key enables exiting the function without saving any changes.
22 Programming SATEL Programming telephone numbers Keep pressing particular keys until the required character appears. Characters available in the keypad are presented in Table 1. Up to 16 characters can be programmed. Some of the special characters (a, b, c, d, # and ) are coded so that the character takes up two items, hence the maximum number of characters available for entering, if they are used, will be lower.
SATEL INTEGRA Plus 23 Entering names Keep pressing particular keys until the required character appears. Characters available in the keypad are presented in Table 3. Hold down the key to display the digit assigned to the key. Shown on the left side in the upper line of the display is information about the letter case: [ABC] or [abc] (it will be displayed after pressing any key and will be visible for a few seconds after the last keystroke).
24 Programming SATEL 3 - information on data writing/reading progress. 4 - icon indicating the status of communication with the control panel: – green color – ready to send data; – alternating green and yellow color – data transmission in progress; – red color – no communication with the control panel; – gray color – COM port disabled.
SATEL INTEGRA Plus 25 - button saves the time in the control panel, based on the computer clock. - the button writes data into the control panel FLASH memory. - button displays a virtual keypad. - the button opens the drop-down menu, which makes available some tools to supervise the system state. - the button opens the „Configuration” window, if the program does not communicate with the control panel, or communicates with it through COM port or modem.
26 Programming SATEL To start the local programming function you can use the [service code] 01 key shortcut. 6. Establishing communication will be signaled on the monitor screen by a corresponding message. 2.2.4 Starting local programming "from pins" If the control panel does not support LCD keypads, does not accept the service code, etc., you can use the emergency procedure of, so-called, starting "from pins.
SATEL INTEGRA Plus 27 2. Connection initialized from the DLOADX program, but the control panel calls back and sets up the connection (built-in 300 bps modem or external analog modem). The control panel may only be remotely programmed from a specified locality. 3. Connection initialized by means of SMS (SATEL GSM module operating as an external modem). 4. Connection initialized by the control panel (all configurations). The control panel may only be remotely programmed from a specified locality.
28 Programming SATEL 4. The DLOADX program will inform you about establishing connection by means of a suitable message. Connection initialized from the DLOADX program, but the control panel calls back and sets up the connection The telephone number of the alarm control panel must be programmed in the DLOADX program ("Identifiers and tel. no" window). 1. Click on the button in the DLOADX program. 2. A drop-down menu will be displayed. Select in it the appropriate control panel modem.
SATEL INTEGRA Plus 29 the "Configuration" window, "Modem" tab). A suitable message will inform about the connection being established. Connection initiated by the control panel – external modem 1. Click on the button in the DLOADX program. 2. A drop-down menu will be displayed. Select the "Modem - INTEGRA with ext. modem" in it. A window will open in which modem initialization information will be displayed. 3.
30 Programming SATEL Configuring the DLOADX program The following parameters required for establishing connection should be programmed in the "Identifiers and tel.
SATEL INTEGRA Plus 31 ISDN/GSM/ETHM MODEM; ANSWERING - ETHM/GSM. You can program the above-mentioned options: using the keypad, in the service mode (OPTIONS submenu); using the DLOADX program during local programming ("Options" window).
32 Programming SATEL address is given in the SMS message (the computer address programmed in the GSM module will be ignored). 6. The DLOADX program will inform you about establishing connection by means of a suitable message. 3. System structure The system can be subdivided into objects (subsystems). Partitions are assigned to each object and zones are assigned to partitions. 3.1 Objects The objects are treated as separate alarm systems. By default, one object is created in the control panel.
SATEL INTEGRA Plus 33 using the DLOADX program, in the "Structure" window, "System" tab, after clicking on the object name – a new partition will be created after you click on the "Add" button. 3.2.2 Programming partitions You can program the partitions: using the keypad, in the service mode, by means of the functions available in the PARTITIONS submenu (STRUCTURE SYSTEM PARTITIONS); using the DLOADX program, in the "Structure" window, "System" tab, after clicking on the partition name. 3.
34 Programming SATEL Partition type Armed with code [Normal] – the partition can be armed/disarmed by the user. With temporary blocking [With time bypass] – the partition can be armed/disarmed by the user, but on arming the partition is blocked for a time indicated by the user or determined by the installer (see DEFAULT BLOCK TIME option). When blocked, the partition can only be disarmed by the user having the ACCESS TO TEMPORARY BLOCKED PARTITIONS right.
SATEL INTEGRA Plus 35 Cash machine block delay [C.mach.blk.del.] – the time counted from the moment of entering the user code of the CASH MACHINE ZONES BYPASSING type. After expiry of this time, the 24H CASH MACHINE type zones will be bypassed. Cash machine block time [C.mach.blk.time] – the time during which the 24H CASH MACHINE type zones will be bypassed after entering the user code of the CASH MACHINE ZONES BYPASSING type. The bypass can be delayed by the CASH MACHINE BLOCK DELAY.
36 Programming SATEL Audible alarm after verification [Bell on 2nd] – if this option is enabled, the alarms from zones with the PRE-ALARM or WITH VERIFICATION option enabled will only trigger loud alarm signaling after verification. The unverified alarms will not trigger loud alarm signaling.
SATEL INTEGRA Plus 37 INT-KLFR, INT-KSG with firmware version 1.02 (or later), INT-TSG, INT-TSI. The value of EOL resistors for the zones in zone expanders with firmware version 4.
38 Programming SATEL 86. ENTRY/EXIT – FINAL). The alarm from the zone will be delayed by a preset time. This makes it possible to disarm the partition before the alarm is triggered. Signaling delay – refers to the 4. PERIMETER, 5. INSTANT and 6. EXIT type zones. Loud alarm signaling can be delayed by a programmed time period. Alarm delay – refers to the 5. INSTANT and 6. EXIT type zones. The alarm from zone may be delayed by a programmed time period. Surveillance time – refers to the 8.
SATEL INTEGRA Plus 39 12. 3EOL/NO – the zone supports a detector of NO type with three EOL resistors in the circuit. Sensitivity – depending on wiring type: NO, NC, EOL, 2EOL/NC, 2EOL/NO, 3EOL/NC and 3EOL/NO – the time during which the zone must be violated, so that it can be noted by the control panel. Roller / Roller 2EOL – 2 parameters are to be programmed: Pulses duration – the time period during which a specified number of pulses must occur (PULSES COUNT) for the zone to be violated.
40 Programming SATEL Max. no violation time – exceeding the maximum time of no violation is recognized by the control panel as a detector failure. The time will only be counted when the zone is disarmed. If the value 0 is programmed, control of this time is disabled. The time can be programmed in hours or minutes. It is recommended that you program the MAX. NO VIOLATION TIME parameter, since it will provide an additional supervision of the detector connected to the zone. 3.3.5 Zone types 0.
SATEL INTEGRA Plus 41 16...31 COUNTING C1...16 – the counting zones will signal an alarm when the number of violations counted during a specified time period exceeds the set value (see: section COUNTERS p. 45). Violations of the counting zones in armed mode can be signaled at the 9. DAY ALARM, 12. SILENT ALARM and 116. INTERNAL SIREN outputs. 32. 24H FIRE 33. 24H FIRE – SMOKE 34. 24H FIRE – COMBUSTION 35. 24H FIRE – WATER FLOW (FIRE) 36. 24H FIRE – HEAT 37. 24H FIRE – PULL STATION 38. 24H FIRE – DUCT 39.
42 Programming SATEL 61. TECHNICAL – GSM LINK TROUBLE – intended for control of the external GSM communication module. Violation of the zone will cause a trouble condition. 62. TECHNICAL – OVERLOAD – intended for control of an additional power supply unit used together with the control unit. Violation of the zone will cause a trouble condition. 63. TROUBLE – violation of the zone will cause a trouble condition. 64...
SATEL INTEGRA Plus 43 CHIME in module – with this option enabled, zone violation can be signaled in partition keypads, code locks and readers expanders assigned to the same partition as the zone (the option CHIME must be enabled in the expander). No alarm sign. in keypad – option for 13. PANIC-SILENT zone type. If it is enabled, alarm from this zone will not be signaled on keypads. Clearing this alarm by means of keypad will not be possible.
44 Programming SATEL Abort delay – when this option is enabled, violating the zone during the entry delay countdown will result in registering a "Zone violation" event (this event can only be reported in the 4/2 format). When the option is disabled, violating the zone during the entry delay countdown will result in registering an "Alarm" event (this event is reported and initiates messaging). Report if not armed – option for the 7. DAY/NIGHT zone type.
SATEL INTEGRA Plus 45 Blocks verification – option for 0-2 and 85-86 zone types. If it is enabled, violation of the zone will block verification of alarms in the partition. All alarms will be unverified until the partition is armed again. Check arm possibility – option for the arming zones (80 and 82 zone types).
46 3.3.9 Programming SATEL Groups of partitions You can define up to 16 partition groups which will be controlled using the 80. ARMING, 81. DISARMING and 83. CLEARING ALARM type zones. The partition groups can be defined: using the keypad, in the service mode, by means of the GROUPS function (ZONES GROUPS). using the DLOADX program, in the ”Zones” window, "Arm/Disarm Groups" tab. 3.3.
SATEL INTEGRA Plus 47 Fig. 6. "Outputs" window in the DLOADX program. 4.1 Output parameters Output name – individual name of the output (up to 16 characters). Output function (see: section OUTPUT FUNCTIONS). Cut off time – time during which the output is active. The parameter is irrelevant for the status indicating outputs. 4.2 Output functions 0. NOT USED 1. BURGLARY – signals all burglary and panic alarms (from zones, keypad/expander tamper, keypad Panic, etc.). 2.
48 Programming SATEL 5. FIRE (FROM KEYPAD) – signals the fire alarms triggered from keypad. 6. PANIC (FROM KEYPAD) – signals the loud panic alarms triggered from keypad. 7. MEDICAL ALARM (FROM KEYPAD) – signals the medical assistance call alarm triggered from keypad. 8. TAMPER ALARM – signals the tamper alarms. 9. DAY ALARM – signals the following: – alarms from 13. PANIC-SILENT type zones, – medical alarms from the 14. MEDICAL - BUTTON and 15. PERSONAL EMERGENCY type zones, – alarms from 7.
SATEL INTEGRA Plus 49 The pulse duration is approx. 0.3 seconds. 24. MONO SWITCH – controlled by users, zones or timers. Using a code, zone violation or turning timer on will activate the output for a preprogrammed time. 25. BI SWITCH – controlled by users, zones or timers. Depending on the current status, using a code or violating a zone will activate/deactivate the output. Turning the timer ON activates the output, and turning the timer OFF deactivates the output. If the 24. MONO SWITCH or 25.
50 Programming SATEL POLARITY option, the output can be used for logical negation). See: LOGICAL FUNCTIONS OF OUTPUTS. s. 55. 47. OUTPUTS LOGICAL OR – active when any control output with normal polarity is active or any control output with reversed polarity is inactive (because of the POLARITY option, the output can be used for logical negation). See: LOGICAL FUNCTIONS OF OUTPUTS s. 55. 48...63 VOICE MESSAGE 1–16 – activated by the telephone messaging function.
SATEL INTEGRA Plus 51 98. REMOTE SWITCH – similarly as types 64-79, but the numbers of remote switches must be selected. 99. ACCESS CARD READ – signals read-in of the user card. 100. CARD HOLD – DOWN – signals holding the user card. 101. CARD READ – EXPANDER – signals that the card has been read in indicated modules/keypads. The 101. CARD READ – EXPANDER type output may be used for execution of the access control function from INT-KLCDR or INT-KLFR keypad.
52 Programming SATEL 115. ARMING TYPE STATUS – active when selected partitions are armed in the selected mode. 116. INTERNAL SIREN – signals the same alarms and violations as the 1. BURGLARY or 9. DAY ALARM output type (logic product of the 1. BURGLARY and 9. DAY ALARM outputs). 117. TAMPERING STATUS – informs about tamper of selected zones, keypads and expanders. 118. KEYFOB BATTERY LOW – informs about low battery in keyfobs belonging to selected users.
SATEL INTEGRA Plus 53 Partitions – indicate the partitions/partition keypads. The output will be controlled by events related to these partitions/partition keypads. Timers – indicate the timers which will control the output. Master users / users – indicate the masters/users. The output will be controlled by events related to these masters/users. Outputs – indicate the output. The output will be controlled by events related to these outputs. Expanders – indicate the expanders.
54 Programming SATEL Output forcing T1 – you can indicate the output which will force the first temperature threshold. If the output is active, the first temperature threshold will be active. When the output is inactive, the control timers will decide which temperature threshold is active. The output 256 cannot be indicated as the forcing one. Timers controlling T1/T2 – you can indicate the timers which will control the temperature threshold.
SATEL 4.9 INTEGRA Plus 55 Output state indicating In case of the 24. MONO SWITCH, 25. BI SWITCH and 64...79 REMOTE SWITCH 1...16 type outputs, the output status can be presented according to the zone status. This is useful, if the control panel output is to only pass a control pulse to switch the device on/off, and the information on the current state of the device is supplied to the control panel zone.
56 Programming SATEL 5. System options Most of the options and parameters described in this section can be programmed: using the keypad, in the service mode, by means of the functions available in the OPTIONS submenu; using the DLOADX program, in the "Options" window. Shown in square brackets are the names used in keypads. 5.1 Telephone options Reporting - TELEPHONE [Mon.TELEPHONE] – with this option enabled, the control panel can send event codes by means of the telephone line.
SATEL INTEGRA Plus 57 No dial tone test [No dialton.tst] – with this option enabled, the control panel will not perform the test for dial tone before dialing the number and will start dialing the number 5 seconds after going "off hook". This makes it possible for the control panel to dial the number when some non-standard tones occur after going off hook (e.g. interrupted tone).
58 5.3 Programming SATEL Other options Permitted "simple" access codes [Simple codes] – with this option enabled, with this option enabled, it is possible to use codes containing less than three different digits (e.g. 1111 or 1212) or consisting of consecutive digits (e.g. 3456). Notify of necessity to change access code [Notify of code] – with this option enabled, the keypad will notify the user of the necessity to change access code, if it is known to other users.
SATEL INTEGRA Plus 59 – LCD keypads, partition keypads, proximity card arm/disarm devices and reader expanders do not signal alarms; – the LEDs in keypads indicate alarms only when code has been entered and confirmed with the key; – the blinking LED in keypads means that there is a trouble in the system, some zones are bypassed, or there has been an alarm; – new access codes in the system must be composed of at least 6 characters (USER CODE MIN.
60 Programming SATEL SIGNAL NEW TROUBLE; ALARM MESSAGES: PARTITIONS; ALARM MESSAGES: ZONES; SHOW VIOLATED ZONES; DISPLAY MODE SWITCHING; – it is not possible to view the status of zones, partitions, alarms, trouble memory and current troubles by pressing and holding down the dedicated keypad keys (the corresponding options are disabled and cannot be enabled); – it is not possible to present information on partition status in the bottom line of keypad display (relevant parameters in the keypad settings wi
SATEL 5.5 INTEGRA Plus 61 Times Global entry delay – parameter taken into account in the delayed zones, for which the programmed ENTRY DELAY is equal to 0. Global alarm time – time of signaling alarm in keypads, proximity card arm/disarm devices, proximity card readers and DALLAS chip readers. No armed indication after – time counted from the moment of partition arming, during which information about armed status is displayed on the keypads.
62 Programming SATEL The service code need not be preceded by a suitable prefix – it is enough when the number of digits preceding the code matches the prefix length. RTC clock correction [Clock adjustm.] – if the accuracy of control panel clock is inadequate, the clock settings may be adjusted once per 24 hours (at midnight) by a defined time. The correction time is programmed in seconds. The maximum correction can be ±19 seconds per 24 hours.
SATEL INTEGRA Plus 63 6. Programming the keypads You can program the keypads: using the keypad, in the service mode, by means of the functions available in the LCD KEYPADS submenu (STRUCTURE HARDWARE LCD KEYPADS) – having selected the SETTINGS or NAMES function, choose the keypad; using the DLOADX program, in the "Structure" window, "Hardware" tab, after clicking on the keypad name. 6.1 Keypad parameters and options Shown in the square brackets are the names, as used in the keypads.
64 Programming SATEL – from zones [Zone al.msg.]. Fig. 8. Example of LCD keypad settings. Code + card – in case of the INT-KLCDR and INT-KLFR keypads, you can define the method of user authorization: – code or card – the user can use code or card; – code and card – the user must use both code and card;; – the authorization method depends on the status of selected output (the output active – code and card; the output inactive – code or card).
SATEL INTEGRA Plus 65 Alarms – you can define which alarms will be triggered from the keypad: – fire – pressing the – panic – pressing the key for approx. 3 seconds. key for approx. 3 seconds. – auxiliary [medical] – pressing the key for approx. 3 seconds. – 3 wrong codes – entering invalid access codes three times. Silent PANIC alarm [Silent panic] – with this option enabled, pressing the key for approx. 3 seconds will trigger the silent panic alarm. Sign. entry delay [Entry time s.
66 Programming SATEL Communication RS – if this option is enabled, it is possible to connect a computer with GUARDX program to the LCD keypad RS-232 port. The option is not available for the INT-KSG and INT-TSG keypads. Quick control [control 8#] – if this option is enabled, the OUTS CONTROL user function can be started by pressing in turn the 8 keys (without the need to enter the user code). Sound volume – the function enables the volume level of sound signal in the keypad to be set.
SATEL INTEGRA Plus 67 Zone state [Zone characters] – you can define the symbols which will illustrate the state of zones. Partition state [Part. characters] – you can define the symbols which will illustrate the state of partitions. Code+arrows – you can define which functions will be started on entering the code and pressing the selected arrow key.
68 Programming SATEL The following can be programmed for each timer: individual name (up to 16 characters); activation/deactivation time: – individually for each day of the week; – daily – the timer will be turned ON/OFF according to these settings, unless it has been programmed for a specific day of the week; arming mode that will be activated by the timer; 4 exceptions – time periods when the timer will be activated/deactivated at a different time.
SATEL INTEGRA Plus 69 The reporting parameters can be programmed: using the keypad, in the service mode, by means of the functions available in the MONITORING submenu; using the DLOADX program, in the "Reporting" window. For correct operation, the reporting function may require enabling some system options. Fig. 11. Example of reporting settings in the DLOADX program.
70 Programming SATEL transmission format required by the monitoring station; identifiers assigned to the alarm system; list of event codes (not applicable to Contact ID and SIA formats). 9.1 Reporting parameters and options See also section TELEPHONE OPTIONS p. 56. Shown in square brackets are the names used in keypads. No module restart reports [No rest. mon.
SATEL INTEGRA Plus 71 Reporting format [Tel. 1 format] – format in which event codes are sent to the monitoring station to the basic telephone number or via Ethernet and using the GPRS technology. Backup format [Tel. 2 format] – format in which event codes are sent to the backup telephone number of the monitoring station. Having selected the CONTACT ID (FULL) or SIA (FULL) format you do not need to program the assignment of identifiers and any event codes.
72 Programming SATEL For the pulse, ADEMCO EXPRESS, CONTACT ID (SELECTED) or SIA (SELECTED) formats, you must define which events will be sent with the given identifier (see: section IDENTIFIERS ASSIGNMENT). For the CONTACT ID (FULL) or SIA (FULL) formats, each object has its own identifier. Therefore, the identifiers of non-existing objects need not to be programmed.
SATEL 9.1.7 INTEGRA Plus 73 Test transmissions The test transmission may be sent: at a specified time. The test transmission code will be sent regularly at a defined time. The number of days between transmissions and the time of sending transmission are programmed. in specified time intervals. The test transmission code will be sent after expiry of a defined time after the last transmission (irrespective of whether it was a test transmission or a code of another event was sent).
74 Programming SATEL – encryption key (STATION KEY) and control panel identifier for the purposes of reporting via Ethernet (ETHM KEY) if the SATEL format is selected, – additional parameters if the SIA-IP format is selected, – identifiers with which the events will be sent, – event assignment (if STATION 1 AND 2 is selected); – advanced options if SIA reporting format is selected. 4.
SATEL INTEGRA Plus 75 10. Messaging The control panel can inform you about the system events by means of: voice messages (the INT-VG module or another voice synthesizer must be connected); PAGER type text messages defined by the installer (the SATEL GSM modules enable the PAGER messages to be converted into SMS); SMS messages with the content consistent with event description in the event log (the SATEL GSM module must be connected to the control panel).
76 Programming SATEL Code – 4 digits which, when entered from the telephone keypad, will acknowledge reception of the voice message. If no code has been programmed to acknowledge receipt of the voice message, nor the ANY CODE option has been enabled, the control panel will recognize receipt of the message as acknowledged when the receiver is picked up after two rings and any sound occurs.
SATEL INTEGRA Plus 77 10.2 SMS messaging parameters and options Name – individual telephone name (up to 16 characters). ON – if this option is enabled, messaging to the given telephone will be possible. Telephone number – telephone number which will be notified. 10.2.1 Events assignment Select the types of events which, if occur in the selected partitions, will result in SMS messaging. 10.3 Starting the voice messaging 1. Enable the TELEPHONE MESSAGING option. 2.
78 Programming SATEL The parameters of telephone answering and control can be programmed: using the keypad, in the service mode, by means of the functions available in the TEL.ANSW./CTRL. submenu; using the DLOADX program, in the "Answering and remote control" window. 11.1 Telephone answering and control parameters and options See also section TELEPHONE OPTIONS p. 56. Shown in square brackets are the names used in keypads. Answer if all chosen partitions are armed [On armed part.
SATEL INTEGRA Plus 79 3. Program the selected outputs as the REMOTE SWITCH. 4. Assign the REMOTE SWITCH type outputs to the users who are to use the function. 12. Control panel firmware update Available on the www.satel.eu website is the current version of control panel firmware and the FLASHX program enabling to write it to the control panel. In order to update the firmware: 1.
80 Programming SATEL 13. Manual update history 2013-08 Firmware version 1.12 2013-12 1.12 Date Introduced changes Information on INTEGRA 256 Plus control panel has been added. Section "Hiding the service mode" has been added (p. 5). List of functions available in the service mode menu has been supplemented (p. 5-21). Note has been added to inform in which situations the local programming function must be disabled (p. 26).