User manual

User Manual INTEGRA 18
When all the LEDs are alternately blinking (from top to bottom), there is no communication
between the keypad and the control panel. This situation may occur when the STARTER
program is running in the control panel or the cable connecting the partition keypad to the
control panel is damaged.
It is possible to program the partition to be armed or disarmed after entering two codes
PROG. In this case, entering the first code causes the LEDs labeled [ARMED] and
[TROUBLE] to blink alternately, while the control panel waits for entering the second code.
Like the LCD keypad, the partition keypad may generate audible signals:
One short beep – acceptance of the code entry (provided that the option ACCES CODE
SIGNALING
(HARDWARE) is enabled).
One long beep – refusal of arming.
Two long beeps – the code is unknown to the control panel.
Two short beeps – acceptance of the first of two codes required for arming or disarming.
Three long beeps – the code cannot control this partition.
Three short beeps – confirmation of partition arming and disarming.
Three pairs of short beeps – it is necessary to change the code – another user, when
changing his code, entered the identical combination of digits to that of the given user, or
the code validity period is expiring.
Four short and one long beeps – confirmation of performance of a control function, code
change, or a guard round.
Five short beeps – the dependent door is open – the door control has not been
performed. To operate the lock it is necessary to close the dependent door and reenter the
code.
The audible signaling may be substituted by the keypad illumination blinking PROG.
The beeps are consequently translated into the keypad extinguishing pulses, when the
backlighting is on, or illumination pulses, when the backlighting is normally off.
The partition keypad may also audibly indicate other situations PROG.
Alarm in partition – continuous sound for the total alarm duration.
Alarm memorylong beeps every two seconds until the alarm is reset. The sounds are
synchronized with the [ALARM] LED blinking. Pressing any numeric key will mute the
signaling for approximately 40 seconds.
Fire alarm – a series of long beeps every second for the total alarm duration.
Fire alarm memoryshort beeps every two seconds until the alarm is reset.
The sounds are synchronized with the
[ALARM] LED blinking. Pressing any numeric key
will mute the signaling for approximately 40 seconds.
Countdown of entry delay – 2 short beeps every second.
Countdown of exit delay – long beeps every 3 seconds, ended with a series of short
beeps (for 10 seconds) and a single long beep. This way of signaling the exit delay
indicates that the countdown is coming to an end before arming.
Autoarming delay time countdown (timer-controlled partitions) – a series of 7 beeps
(of ever shorter duration).
Door open too long – short beeps repeated with a high frequency until the door is
closed (with door control function activated).
Chime in expander – five short beeps – information on violating selected zones in the
partition (CHIME option must be enabled in the partition keypad, and CHIME
IN MODULE
option must be active for the zone).
Using the partition keypad you can control the armed mode in one partition and execute the
access control functions for a single door (door lock control).