User manual
INTEGRA SATEL
25
Fig. 8. Code lock type INT-SZK-GR.
The basic function of the code lock is to control access to the room where the door provided
with electric catch, bolt or electromagnetic interlock is installed. The lock may also be used
for partition control during a guard round in the facility.
In order to open the door, enter the user CODE from the lock keypad and press [#] or [
*
].
The user must be authorized to use the particular code lock.
[CODE][#] door opening
[CODE][
*
] door opening
Note: Entering a wrong (not recognized) code three times may:
− trigger an alarm PROG;
− block a code lock for 90 seconds. After this time each next wrong code entering will
block the code lock PROG.
The code lock keypad can be used to change the user code, the change procedure being
the same as for the partition keypad.
The following special alarms can be quickly triggered from the code lock keypad:
− FIRE alarm – press and hold down the (INT-SZ-GR / INT-SZ-BL) or
(INT-SZK-GR) key for approx. 3 seconds;
− AUX (medical) alarm – press and hold down the (INT-SZ-GR / INT-SZ-BL) or
(INT-SZK-GR) key for approx. 3 seconds;
− PANIC alarm – press and hold down the (INT-SZ-GR / INT-SZ-BL) or
(INT-SZK-GR) key for approx. 3 seconds.
Acknowledgement of acceptance by the control panel of the called control function (by sound
or illumination of the code lock keypad) is identical as for the partition keypad..