which prevented arming has been in the meantime removed, the partition will be armed.
Otherwise, the list of causes which prevent arming will be displayed again.
If the SERVICE MESSAGE AFTER TAMPER ALARM and DO NOT ARM IF TAMPERED options are
enabled by the installer, the arming will only be possible after repairing the tamper and
clearing the message by using the service code.
If the arming by means of the LCD keypad is impossible because:
a zone with enabled PRIORITY option is violated;
the DO NOT ARM IF TAMPERED option is enabled and the zone is tampered (type 2EOL
zone, too long violation of the zone or too long non-violation of the zone),
you can bypass the selected zone by pressing the key [4] during review of the causes
which prevent arming. Bypassing is possible when the user has a suitable authority level,
and the installer has allowed the zone to be bypassed (the BYPASS DISABLED option is not
enabled for the zone).
If the option WARN WHILE ARMING IF TROUBLE is enabled, the partitions are armed from the
LCD keypad and there are troubles in the system, the control panel will inform the user of
it with a suitable message before arming. Pressing the key [1] will arm the partition(s), and
pressing the key [2] will display information on troubles. Pressing the [
*
] key will make it
possible to cancel the arming and trouble review. If the key [2] was pressed, there will be
return to the question about arming or trouble viewing after the review is completed and
the [
*
] key is pressed.
If the arming is performed by means of the LCD keypad in a partition with temporary
blocking, the control panel will ask to indicate the block time before arming.
If the option VIOLATED/BYPASSED ZONE PREVIEW WHEN ARMING is active and the arming is
performed from the LCD keypad, the control panel will check that there are no
violated/bypassed zones. Checked for possible violation are the zones for which the
PRIORITY option has not been enabled. If violated or bypassed zones are found, the
following message will be displayed on the keypad: "Viol./Bypass z. 1=Arm 2=Check".
Pressing the key [1] will arm the partition, and pressing the key [2] will display information
on violated/bypassed zones. The [
*
] key will cancel the arming and viewing. If the key [2] is
pressed, the question about arming and viewing will be asked again after completion of the
viewing and pressing of the [
*
] key.
In case of zones for which the exit delay time has been programmed, the arming will take
place after the countdown ends. It is possible to terminate the exit delay countdown and arm
the partition immediately by entering [9][#] from the keypad or partition keypad PROG.
Reduction of the exit time is only possible on the same keypad/partition keypad from which
the arming was done.
A special armed mode can be enabled in the partition to allow the user to stay in the facility
where the system has been armed:
full arm with bypass – the zones with enabled BYPASSED IF NO EXIT function will be
bypassed, i.e. the control panel will not respond to their violation. Otherwise, the facility is
normally protected.
armed without interior – the control panel will not react to violation of the interior zones
(zone type 3. I
NTERIOR DELAYED). The exterior zones (zone type 8. EXTERIOR) will trigger
silent alarm. Otherwise, the facility is normally protected and all functions are executed.
armed without interior and without entry delay – the control panel will react in the
same way as above, but, additionally, the delayed zones (zone type: 0. E
NTRY/EXIT,
1. ENTRY, 2. DELAYED WITH DELAY SIGNALING) will act as instant ones.
In order to enable the special armed mode by means of LCD keypad, do the following:
1. Enter ACCESS CODE and press the [
*
] key.