User manual
INTEGRA SATEL
45
Disarm (2codes)
The function is available when at least one partition in the system requires entering two
codes to be disarmed. After starting the function, select the partition(s) to be disarmed ( -
partition selected; - partition not selected) and confirm using the [#] key. Depending on how
the partition has been configured by the installer, it may also be necessary to determine the
code validity period. If the code validity time is not programmed by the user, it will be 60
seconds. The first code can be optionally cancelled (see the CANCEL 1ST CODE function).
The partition will be armed after the second code is entered (in case of the LCD keypad, the
user using the second code must run the DISARM function, and in case of the partition keypad
- enter the code and confirm with [#]). During the first code validity period, the and
LEDs are alternately blinking in the partition keypads.
The installer can configure the partition so that the second code must be entered from
a different keypad than the first code.
Defer auto-arming
The function puts off (delays) arming of a timer-controlled partition (auto-arming). It is used
for programming the value of time interval by which the moment of automatic arming of
a partition is to be delayed. The maximum delay time is 4 hours, 33 minutes and 3 seconds.
Entering a higher value will set the maximum permissible value, while entering the zeros
alone will cancel the timer-controlled arming until the particular timer is activated again.
Operation of this function pertains both to the partition timers programmed by the user, as
well as to the those programmed by the installer.
The function makes it possible to select the partitions where the countdown of the
auto-arming delay has begun. Exactly this feature distinguishes the said function from the
described below SET AUTO-ARMING DELAY user function which gives access to all the partitions
armed automatically with time delay and available to the individual user. In view of a low
value of the auto-arming time (max. 255 seconds), it is important that a quick option of the
partition arming delay be available in case it is necessary to stay inside.
Upon commencement of the countdown, the control panel can display on the LCD keypad
the partition name and the delay time which remains to arming PROG. If the time is
simultaneously counted in several partitions, the display shows the name of the partition
which will be armed first.
The delay time is programmed individually for each partition for which the auto-arming delay
countdown has begun.
Set auto-arming delay
The function puts off (delays) arming of a timer-controlled partition (auto-arming). It is used
for programming the value of time interval by which the moment of automatic arming of
a partition is to be delayed. The maximum delay time is 4 hours, 33 minutes and 3 seconds
.
Entering a higher value will set the maximum permissible value, while entering the zeros
alone will restore the partition control according to the installer’s settings. Operation of this
function pertains both to the partition timers programmed by the user, as well as to the those
programmed by the installer.
The delay time is programmed individually for each automatically controlled partition.
The function is available in the user menu if the user is authorized to get access to at least
one partition for which a non-zero "auto-arming delay" time has been set PROG.
The value of such a delay may vary from 1 to 255 seconds.
Activation of the timer controlling the particular partition starts the process of counting the
auto-arming delay time. Then, countdown of the partition exit delay takes place (if any),
followed by arming of the partition.