User manual

INTEGRA SATEL
51
inhibited (or unbypassed) will be displayed. Use the S and T keys to scroll through the list.
Shown in the top right corner of the display is an additional symbol:
– zone is not bypassed;
– zone is inhibited;
– zone is isolated.
Pressing any number key will change the displayed symbol to one of the following ones:
– the zone is to be inhibited;
– the zone is to be unbypassed.
Press the X or W key to switch the keypad over to graphic mode. The current status of all
available zones that can be bypassed/unbypassed is presented on the display by means of
the , and symbols. The X key will move the cursor to the right, and the W key to the
left. If the list of zones is longer than 32, press X when the cursor is on the last item to
display the next group of zones, or press W when the cursor is on the first item to display the
previous (or the last) group of zones. Bypassing/unbypassing a zone is effected in the same
way as in the text mode. Press the T or S key for the keypad to return to the text mode.
Termination of the function by pressing the [#] key will bypass/unbypass selected zones.
Isolate
The function is available to the users having the ZONE BYPASSING and ZONE ISOLATION rights.
The isolated zone will remain bypassed until unbypassed by the user. The manner of
indicating the zone status and the procedure are identical to those used for zone inhibiting.
Press a number key to change the currently displayed symbol to:
– the zone is to be isolated;
– the zone is to be unbypassed.
Set time
The function makes it possible to enter the actual time and date in the alarm system.
The data are entered in the following format:
time – HH:mm:SS (hour:minute:second),
date – DD:MM:YYYY (day:month:year).
New data should be entered from the keypad by typing the correct digit at the place of the
cursor flashing. After the digit is entered, the flashing indicator moves to the next position on
the right. The cursor can also be moved by using the W and X keys.
Troubles
This function makes it possible to view the troubles which have occurred in the alarm system.
It is only accessible when the [TROUBLE] LED is blinking on the LCD keypad and partition
keypads. The list of possible trouble messages is included at the end of this manual
in APPENDIX A.
The name of particular element (entered by the installer) appears in messages related to
zones, expanders and keypads, in the bottom line of the display. No additional message is
displayed at the end of this function.
Note:
If any emergency situation occurs in the system, it is necessary to report the fact
immediately to the alarm system service person, and rectify the cause of the trouble alarm.
The troubles also include tamper information.