53
Selection of partitions influences the contents of the list displayed when viewing event types
from 1 to 4 (event type numbers according to the list given below).
List of event types:
1. Zone & tamp.al. - alarms for zones, tamper alarms.
2. Other alarms - other alarms. fire, auxiliary, technical alarms, no guard round.
3. Arm/Disarm/Clr - arming and disarming, alarm clearing.
4. Zone bypasses - bypassing/unbypassing zones.
5. Access control - use of keypads and proximity card readers for controlling
electromagnetic door locks, door status monitoring, temporary blocking
of partitions.
6. Troubles - technical problems in the system, restarts of modules.
7. Functions - calls for user functions to control the operation of the control panel.
8. System - service mode, clock programming, etc.
Note: The messages about the following event types are not displayed in the event lists on
the LCD keypad:
- PANIC alarm,
- Silent PANIC alarm,
- DURESS alarm.
Reset zones
The function temporarily disables the type 43. RESETABLE POWER SUPPLY outputs. These are
dedicated outputs for powering detectors with operation memory (e.g. fire detectors).
A momentary outage will cause reset of the detectors supplied from these outputs, i.e. reset
of the alarm memory.
Clear latched outputs
The function clear outputs of control panel working in the “latch" mode. It does not affect the
alarm outputs which remain active until alarm is canceled.
Some outputs in the system may work in the “latch" mode as indicators of the use of selected
codes or violation of selected zones. The “latch" type functioning prevents the activated
output from returning to its basic state until it is deactivated with the herein described
function.
Fire door opening finished
This function is connected with the new option of access control modules (the option makes
possible to define the door unblocking rules in case of fire). It ends unblocking of the doors
and restores normal operating status in all access control modules.
Change options
The submenu provides access to the functions described below.
Keypad chime – signals the violation of any zone (detector) selected by the installer. Some
zones may be selected which will activate signaling in the keypad. The chime signal in
each keypad may be activated from different zones. The function makes it possible to
disable and enable this signaling in the keypad from which it was called.
Outputs chime – the function makes it possible to block the signaling of zone violations from
selected partitions on the C
HIME type output, provided that the installer permits blocking for
those partitions.
Partition timers (see section S
YSTEM ARMED MODE) allow automatic zone arming and
disarming.