User manual

User Manual INTEGRA 54
For the timer to operate it is necessary to:
1. Start the ACTIVE function and enable it ( ).
2. Select operation mode: everyday or weekly.
3. Set the timer on and/or off time.
In case of the daily cycle timer, after selecting the mode, the "Every day timer turned
on: HH:MM" text will appear on the display. Enter the hour (HH) and minute (MM) of
switching the timer on. Press S or T to enter hour and minutes of switching the
timer off.
For the weekly cycle timer, the time of switching on and/or off is programmed in the
same way, but it should be done for each weekday separately.
Note: Entering the nines only will deactivate the given function (arming or
disarming).
Example: The timer may arm only at a specified time, but disarming must be done by
the user himself; automatic partition control may be activated on some
weekdays only.
4. Determine the armed mode which should be enabled by timer: 1 – fully armed,
2 - armed without interior, 3 – armed without interior and without entry delay. By default,
the control panel assumes that each new timer enables the fully armed mode (type 1).
5. Confirm the entered data by pressing [#]. The name of the timer set will be displayed,
together with preprogrammed data.
6. Save the timer settings in the control panel memory. For this purpose, press the [
*
] key
and accept the changes with the key [1].
No expanders tamper alarms – should any problems occur in communication with the
expansion modules, report it to the service. The function allows to temporarily disable the
expander tamper control.
Permanent service access – this option is available to the master user (administrator). If
enabled, the service has permanent access to the alarm system, which, among other
things, enables the control panel to be programmed by using LCD keypad or DLOADX
program.
Note: Enabling the option will clear the service access time programmed with the SERVICE
ACCESS
function. On the other hand, programming the service access time by means
of the S
ERVICE ACCESS user function will disable the PERMANENT SERVICE ACCESS
option.
Service can edit – the option is available to the master user (administrator). If selected, it
allows the service to add, edit and delete users in the administrator's object.
Service arm/disarm/clear/bypass – the option is available to the administrator. If it is
enabled, the service personnel can arm/disarm the system, clear alarms and bypass
zones in the administrator object.
Permanent DloadX access – the option is available to the administrator. If enabled, the
control panel can be programmed by means of the DLOADX program, irrespective of
whether or not the service has access to the alarm system.
DloadX IP – the function enables programming the address of the computer, on which the
DLOADX program is installed. The address must be set if the control panel is to initiate
communication with the DLOADX program through Ethernet, using the TCP/IP protocols
(see: description of the ETHM-1 – DLOADX function, available in the DOWNLOADING
submenu). It can be entered as a name or IP address.