GuardX IP – the function enables programming the address of the computer, on which the
GUARDX program is installed. The address must be set if the control panel is to initiate
communication with the GUARDX program through Ethernet, using the TCP/IP protocols
(see: description of the ETHM-1 – GUARDX function, available in the DOWNLOADING
submenu). It can be entered as a name or IP address.
Clear service message – it is possible to delete the service message which is displayed by
the installer using a suitable service function. The installer can define the user(s)
authorized to deactivate the display of technical information, such a user getting access to
the option described herein.
Tests
The submenu provides access to the diagnostic functions.
Partitions – checking the current status of partitions accessible to the given user and
operated from the LCD keypad. The partition status is shown in the form of a suitable
symbol (character) adjacent to the number (numbers around the keypad display) which
corresponds to the partition number in the system. The installer assigns symbols
(characters) to particular situations.
b – temporary partition blocking,
? – entry delay,
E – exit delay (less than 10 seconds),
e – exit delay (more than 10 seconds),
P – fire alarm,
A – alarm,
p – fire alarm memory,
a – alarm memory,
a – zone is armed,
– violated zones,
– zone is disarmed, zones OK.
Note: The characters shown above are default settings which can be changed. The installer
should inform how the particular states of zones and partitions will be identified on the
display.
Zones – checking the current status of zones in the partitions available to the user and
operated by means of this keypad. Zone status is shown in the form of a symbol
(character) next to the number (numbers around the keypad display) which corresponds to
the zone number in the system. The installer assigns symbols (characters) to particular
situations. Information on zones is displayed, depending on the control panel size, in, 2 or
4 (INTEGRA 128) groups (see p. 11, description of [GROUP] LEDs). On starting the
function the status of zones 1-32 is displayed. Press the X key to display the status of the
next group, or the W key to display the previous group. The amount of available
information depends on the type of detector connected to the zone. The detectors
configured as 2EOL provide the most information.
It is possible to read the following information of zones:
b – zone bypass,
l – trouble "long violation",
f – trouble "no violation",
T – tamper alarm,
A – alarm,