Keypad name – the function shows on display the name of particular keypad (default or
installer assigned).
File in DLOADX – the function displays the date and time of writing the computer data
(DLOADX program) to the control panel, as well as the name of data file.
Panel version – the function shows the current control panel firmware version number on the
keypad display.
ST program version – this function displays on the keypad monitor the number of current
firmware version of the processor handling the mainboard ABAX wireless system and the
mainboard zones. The function is only available in the INTEGRA 128-WRL control panel.
GSM IMEI/v/sig. – this function makes it possible to check the level of signal received by the
GSM telephone antenna, individual identification number of the telephone, and the
telephone version. The S and T keys are to be used for scrolling through the displayed
information. The function is only available in the INTEGRA 128-WRL control panel.
IP/MAC ETHM-1 – the function displays the IP address and MAC number of the ETHM-1
module connected to the control panel.
Module versions – the function makes it possible to check the firmware version of the
devices connected to keypad/expander bus.
Note: Not all modules are supported by this function.
Time synchronization the function makes it possible to manually initialize synchronization of
the control panel clock with the time server (automatic time synchronization takes place
everyday at 05:30). It is available to the installer or administrator. It refers to the
INTEGRA 128-WRL control panel and any other panel to which the Ethernet module is
connected. The time synchronization server address must be programmed in the control
panel.
Note: If the time synchronization is going on (initialized automatically or manually), the
function is unavailable.
Service access
The function determines the time of service access to the alarm system. The time is
programmed in hours. Programming the value 0 means that the service access is excluded.
Note: Enabling the PERMANENT SERVICE ACCESS option will clear the preprogrammed service
access time (the 99 hour value will be entered automatically, but the countdown will
not start).
When the service has access to the alarm system, the service code is accepted by the
keypads and the control panel can be programmed from the LCD keypad or D
LOADX
program.
Open door
By using this function it is possible to open any door controlled by the alarm system (CARD
READ
EXPANDER type outputs, partition keypads, code locks and proximity card/DALLAS
chip reader expanders).
Outputs control
The function is available to the users with assigned „Control” right. It allows the user to
enable/disable single outputs, type MONO SWITCH, BI SWITCH, REMOTE SWITCH, SHUTTER UP
and SHUTTER DOWN, and, thereby, to operate particular devices. In order to make the output
available for control, it must be assigned by the installer to one of the 4 output groups.
An individual name can be assigned to each group.