User manual

INTEGRA SATEL
59
SHUTTER UP. The current status of the outputs is indicated on the display next to the output
name in the following way:
- outputs inactive (off),
Ç - SHUTTER UP output active (on),
È - SHUTTER DOWN output active (on).
Only one of the outputs can be activated at a time. After pressing the [#] or X key, a line
mark appears under the field, in which the output status is displayed. Pressing the S key will
activate the SHUTTER UP output (if both outputs were inactive) or toggle the SHUTTER DOWN
output to its inactive state (if it was active). Pressing the T key will activate the SHUTTER
DOWN
output (if both outputs were inactive) or toggle the SHUTTER UP output to its inactive
state (if it was active). Irrespective of which output is currently active, it will be deactivated by
pressing any numerical key. When the control is over, press the [#] or W key to go back to
the list of controllable outputs (the line mark under the output status field will disappear).
Service mode
The function starts a special control panel operation mode and displays the list of service
functions. The control panel does not signal alarms from most of zones (including tamper
alarms), it only responds to violation of some zones armed for 24 hours and to alarms from
partition keypads and code locks (hold-down functions). The control panel remains in the
service mode until exiting it with the E
ND OF SM function (from the service functions list).
The function is accessible after enabling the service access by the master user and entering
the service code.
Take SM over
The function makes it possible to switch over the operation control of the control panel being
in the service mode to a keypad other than that from which the service mode was called.
The function, which is accessible to the service only, is intended for use in large facilities,
with several keypads installed, to facilitate the installer's work.
Downloading
The submenu contains functions related to communication with the computer on which
suitable software is installed for configuration and operation of the security alarm system.
Availability of the functions depends on configuration and settings of the alarm control panel.
Start DWNL-RS – the function starts communication through the RS-232 port of control
panel. Available to the service only.
Finish DWNL-RS – the function ends communication through the RS-232 port of control
panel. Available to the service only.
Start DWNL-MOD. – the function starts communication through the external modem (analog,
GSM or ISDN).
Start DWNL-TEL – the function starts communication through the built-in 300 bps modem.
Start DWNL-CSD – the function starts communication through the built-in GSM
communicator, using CSD technology. only INTEGRA 128-WRL
Start DWNL-GPRS – the function starts communication through the built-in GSM
communicator, using GPRS technology. only INTEGRA 128-WRL
ETHM-1 – DloadX – the function starts communication with the computer with the DLOADX
program through the Ethernet network, using the TCP/IP protocols (the ETHM-1 module
with firmware version 1.03 or later must be connected to the control panel).
ETHM-1 – GuardX – the function starts communication with the computer with the GUARDX
program through the Ethernet network, using the TCP/IP protocols (the ETHM-1 module
with firmware version 1.03 or later must be connected to the control panel).