User's Manual

SATELLAR Radio Unit User manual v.0.7
9
2) SATEL NMS PC software
Once deployed status monitoring and configuration can be performed using a Windows
based SATEL NMS PC software through the RS-232/485 interface of the Radio unit. This
is also possible over the air: the status and configuration data of a distant radio modem
can be accessed through a radio connection.
Flexible and expandable
The SATELLAR concept has been designed to be flexible and expandable both in terms of
hardware and software functions. This can also be seen when using the Radio unit alone.
Modulation level
Several different modulation methods (2-, 4-, 8-, and 16-FSK) are offered. If the
customer requires a long range radio connection he/she selects a low level modulation.
On the contrary, if a high data rate is the primary concern a high level modulation must
be selected.
Channel width
Two different channel widths are supported and can be selected by changing software
settings – without a need to modify the hardware
FEC (Forward error correction) and interleaving
To extend the radio range in a noisy environment (at the expense of the data rate) a
forward error correction algorithm (FEC) can be used. The Radio unit offers two different
code rates for forward error correction. In packet mode of data transfer the forward error
correction is used together with interleaving to minimize the effect of errors occurring in
bursts. In the transparent mode the forward error correction is used without interleaving
to minimize the latency.
Adjustable output power
RF output power is adjustable with high resolution allowing the customer to select the
output power just according to the local conditions of the radio link.
Expansion units
Due to the modular mechanical structure of SATELLAR it is possible to add hardware expansion
units, even later as an update. Related to Radio unit the most relevant expansion units are:
A booster unit for higher output power
A serial port extender unit: a unit offering two or more serial ports, possibly of
different types (RS-232, -422, -485)
I/O extension (for site monitoring and simple I/O control)
For the availability of different expansion units contact your local distributor.