Section 3: Configuration and Operation
Page 3-20      LM Basic 408e/412e Operator’s Manual
3.12 MAINTENANCE MODE
3.12.1 Factory or All Clear Mode 
In this mode, the status of DSW2-4 determines whether you can 
access the Factory mode or the All Clear Mode. Set DSW2-4=ON 
first. Then the printer will remain Maintenance Mode until the 
DSW2-4 is set to OFF.
In the Factory Mode settings, you can change the following: Counter Clear, Print Size for test 
print width, and Start/Stop test print. In All Clear settings, you can clear the Counter/EEPROM.
3.12.2 Factory Mode 
In this screen you can choose to perform an All Clear for all the 
counters, or clear on the Head Counter. 
The default value is NONE. Use the LINE button to select NONE, 
ALL or HEAD as required.
Press the FEED button to confirm the reset and proceed to the next 
screen.
3.12.3 Test-Print Width 
In this screen you can choose either a SMALL or LARGE test print. 
The default value is LARGE.
On the LM408e/412e, the value for SMALL is 40mm, and for LARGE, the value is 104mm.
Use the LINE button to select SMALL or LARGE, then press the FEED button to confirm the 
setting and proceed to the test print.
3.12.4 Start/Stop Test Print
This screen appears during the actual test printing. 
Press the FEED button to stop or resume the test printing.
 COUNTERS MODE
 COUNTER CLEAR
    NONE
 COUNTER CLEAR
    ALL
 COUNTER CLEAR
    ALL
 COUNTER CLEAR
    HEAD
 COUNTER CLEAR
    NONE
TEST PRINT
 PRESS FEED KEY