Service manual
PN 9001098
Rev. A
2-27
SATO M-10e TT/DT Printers Service Manual
Section 2. Configuration
STEP PROCEDURE
2. Now pull the label forward until the “EYE” mark is positioned under
the sensor (the voltage reading shoould be at its highest point). Record
the voltage shown on the top line of the LCD panel. The voltage ranges
measured should be within the following ranges:
Label only = Less than 1.0V
Eye-mark = 2.5V to 3.5V
If the measured values are outside this range, you may have trouble
finding a value that will work properly under all conditions. If this is
the case, a higher quality label may be needed to get adequate
performance.
3. Calculate the starting point voltage using the formula.
4. Use the LINE/FEED keys to step the counter to the desired setting.
The reading will advance to a setting of 4.9 (the maximum vlotage). If a
value of “0.0” is set, the printer will automatically set the level each
time the printer is powered on with labels loaded or the head is closed.
5. Once the setting is correct, press the ENTER key to accept the setting
and advance to the next display.
LCD Panel — Service Mode
Eye [X.XV]
Input [X.XV]
This selection specifies whether or not the printer will automatically feed a blank label when it
is placed in the Online mode
Auto Online Feed
Yes No
auto online feed
yes no
STEP PROCEDURE
1. Use the keys to step the cursor to either YES or NO.
If Yes is selected, the printer will feed a blank label anytime it enters
the Online mode.
2. Once the correct setting is selected, press ENTER to confirm the
setting and advance to the next screen.