User manual

TECHNICAL DATA
Height mm 850
Width mm 595
Depth mm 635
Volume (net) Litre 92
Energy consumption kWh/y 132
Rising time Hours 24
Freezing capacity Kg/24h 14
Climatic class SN-T
The technical information are situated in the
rating plate on the internal left side of the
appliance and in the energy label.
INSTALLATION
Read the "Safety Information" carefully
for your safety and correct operation of
the appliance before installing the
appliance.
Positioning
This appliance can be installed in a dry, well
ventilated indoor (garage or cellar) also, but
for optimum performance install this appli-
ance at a location where the ambient tem-
perature corresponds to the climate class
indicated on the rating plate of the appli-
ance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
Levelling
When placing the appliance ensure that it
stands level. This can be achieved by two
adjustable feet at the bottom in front (2). If
necessary adjust the feet by removing the
spacer (1).
1
2
Location
The appliance should be installed well away
from sources of heat such as radiators,
boilers, direct sunlight etc. Ensure that air
can circulate freely around the back of the
cabinet. To ensure best performance, if the
appliance is positioned below an overhang-
ing wall unit, the minimum distance be-
tween the top of the cabinet and the wall
unit must be at least 100 mm . Ideally, how-
ever, the appliance should not be posi-
tioned below overhanging wall units. Accu-
rate levelling is ensured by one or more ad-
justable feet at the base of the cabinet.
If the cabinet is placed in a corner and the
side with the hinges facing the wall, the dis-
tance between the wall and the cabinet
must be at least 10 mm to allow the door to
open enough so that the shelves can be re-
moved.