User guide

27
Picture 1 - The temperature sensor and the cables of the
control panel may not touch the dotted area in the picture
(400 V). Shorten the cables and hide them.
The heater seen from below and in cross section
Wiring diagram for control panel and temperature sensor
Control panel cable
1
2
3
4
Blue
White
Red
Yellow
Sensor cable
A1
A2
A3
A4
A5
White
Brown
Green
Yellow
Grey
Control panel cable
B1
B2
B3
B4
B5
Pink
Blue
Red
Black
Violet
Information to the installer
Output
(kW)
Fuse
(A)
Heater connection
HO7RN-F (mm
2
)
(t ex RHH or VSB)
Permanent
connection
from fuse (mm
2
)
4,5
6,5
9,0
3 x 10
3 x 10
3 x 16
5 x 1,5
5 x 1,5
5 x 1,5
5 x 1,5
5 x 1,5
5 x 2,5
Facts about the connection of the
heater to the electric network
Output (kW) Heating element (230 V)
SEPC 186
2170 W
SEPC 187
3000 W
4,5
6,5
9,0
x 3
x 3
Heating element
x 3
SEPC 185
1500 W
x 3 = three elements
Sensor cable