User guide

SAUNATEC HELO HSX Steam generator
10
User and Service Manual
Digital Control for HELO HSX Steam generator
WARNING
Installation and mending must be performed by qualified personnel in the respect of all the following safety
norms:
DLGS N°615/96 del 12/11/96 (ECC Document 89/336 on Electromagnetic compatibility)
DLGS N°626/96 del 26/11/96 (ECC Document 93/68 on Low Voltage)
The present manual is addressed to technical personnel qualified for installation
PRODUCT DESCRIPTION
The “HSX DIGITAL CONTROL PANEL” System is an electronic device that controls the following functions:
Steam Bath On/Off
Adjustable bathing time and temperature
Light
Fan
Essence Pump
4 programmable/preset programs
Alarm analyses
DESCRIPTION OF CONNECTIONS
Power inlets
1 serial inlet for the keyboard
2 resistive level sensors (predisposed for capacitive or ultrasound level sensors)
Supply 5VCC, digital exit: open collector NPN
The high level sensor has to have adjustable sensitivity
2 dip switch
1 normally closed connector for a remote timer
Outputs
1 serial output for controlling the next control (without using a split box)
1 lamp 12VAC – 35 WATTS MAX.
1 water-charging electro valve 230 VAC
1 drain electro valve 230 VAC
1 essence pump A 230VAC MAX 400WATTS.
1 fan 230VAC MAX 400WATTS.
1 steam generator output (remote control switch coil) 230VAC MAX 3000W
Details
Board dimension: 10CMX11 CM
Second transformator to supply level sensors