4
4
LOW LEVEL SENSOR INPUT
HIGH LEVEL SENSOR INPUT
SENSIBILITY TRIMMER
DELAY TRIMMER
INPUT VOLTAGE (12 VAC)
FROM TRANSFORMER
LAMP OUTPUT (12VAC 40W)
SERIAL OUTPUT GOVERNING
THE NEXT CONTROL BOARD
CONTROL
KEYBOARD
NORMALLY OPEN INPUT
FOR REMOTE TIMER
230/12VAC 42VA
TRANSFORMER
INPUT MAIN POWER
SUPPLY (230VAC)
OUTPUT POWER SUPPLY
TO TRANSFORMER (230VAC)
HEATER OUTPUT (230VAC)
BOILER
FILLING
ELECTROVALVE (230VAC)
BOILER EMPTYING
ELECTROVALVE (230VAC)
ESSENCE OUTPUT
PUMP (230VAC)
FAN OUTPUT (230VAC)
HELO HSX DIGITAL CONTROL CONNECTION DIAGRAM
J1 Jumper for operation mode (continous / timer)