User guide
SAUNATEC HELO HSX Steam generator
13
STEAM BATH FUNCTION
.
Temperature and Time setting
The temperature set by default is 45°C and it can be changed from 30°C to 50°C with steps of 1°C by using
the plus and minus key. The temperature can be changed also after the set steam bath program has
started, by pressing the temperature key and subsequently the plus and minus keys within 2 seconds.
Time can be changed by using the time key and the plus and minus keys.
The Steam generator
When the user starts the treatment the electro valve starts taking in water, when the water reaches the low
level sensor the heating starts.
When the water reaches the high level sensor the electro valve closes off; as soon as the high level sensor
does not feel the water the electro valve opens and it closes when the right level is reached.
Steam generator cleaning cycle
The cleaning cycle is an automatic operation and is very important because it prevents the formation of
chalk and bacteria in the water tank.
It is automatically activated 15 minutes after the steam generator has stopped. The drain electro valve
opens for 2 minutes. The tank is filled with water up the high level sensor, and the draining electro valve
opens again for two minutes.
During the cleaning cycle the external segments of the display go around in circles.
LAMP
The led is on when the lamp is off. Press the lamp key and the led switches off while the lamplight is on.
The lamp works independently from the steam generator .
FAN
The fan switches on automatically when the generator stops, and then the fan runs for 30 min.
During the steam bathing the fan can be switched on and off.
The led shows the status of the fan: on when the fan works and off when the fan is off.
ESSENCE PUMP
The essence pump starts working automatically when the set temperature is reached. It can stopped and
restarted by pressing the essence pump key. The led is on when the pump is on and off when the pump is
off.
PRE PROGRAMMABLE BUTTONS ..
There are 4 memory keys with default steam bath programs.
In order to memorize a personal steam bath, adjust temperature and time by using the plus and minus keys
and then press a memory key for more than 2 seconds: in this way the customized steam bath program is
saved in the memory key. The Memory keys all work as starting keys for the steam bath program
The led of the memory key is on when the chosen steam bath program is on. When the user is
programming a key the led blinks, while saving the new data, in order to show that the reprogramming
operation has been successfully performed.
ALARMS
If a problem occurs in the system while in function, the display visualizes an alarm number (A1, A2, A3, A4),
which helps identify the nature of the problem.
• A1: If the high level sensor does not feel the water after 5 minutes from activating the steam bath,
the system times out and it can be re-started. If the system does not get restarted after 5 minutes
then the draining valve empties the water tank.
• A2: If the low level sensor does not feel the water for more than 1 minute during the treatment, the
heating stops working. If the operator doesn’t make any operational actions within 5 minutes then
the whole system times out.
• A3: If the set temperature is not yet reached after 30 minutes the display visualizes the alarm. The
steam bath continues according to program. Check the set temperature, sensor position, ventilation
and dimensioning of the generator if the A3 shows again.
• A4: If the temperature level does not work all functions are inhibited