User guide

SAUNATEC HELO HSX Steam generator
18
Start
Press
pushbutton
RL1
engages
LD1
on
Solenoid Valve opens
Water into tank
(appr.1min 20sek)
Water tank is full.
RL5
engages
Heating element activates
Boiling off water in the Tank. Steam into
room
Waterlevel low
LD1
off
RL1
engages
Solenoid valve opens
water is filled to high level
-check power supply
-check relay
-Tank is allready filled with water
-check watersupply
-check solenoid valve
-check wiring
-check waterlevel probe
-check waterlevel probe
If time to fill tank longer than 1.30 min
-check water pressure
-check solenoid valve for dirt particles
-check drain valve for leakages
-check termofuse
-check heating elements
-check relay
If water boils but no steam to room
-check steam pipe and steamoutlet
HSX Flowchart
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO