Electrical supply
Fused mains electricity should be terminated with an isolator adjacent to the steam generator. The
supply should be rated according to the generator to be fitted and not less than the following:
Power 400V – 415V 3N~ 230V-240V 1N~ 230V 3~
3.4kW 5 Amp 15 Amp 8 Amp
4.7kW 7 Amp 20 Amp 12 Amp
6.0kW 9 Amp 26 Amp 15 Amp
7.7kW 12Amp 33 Amp 19 Amp
9.5kW 15Amp ----- 24 Amp
12 kW 19Amp ----- 30 Amp
14 kW 23Amp ----- 35 Amp
An isolation switch should be fitted in a convenient location outside the bathroom area so that the
generator can be switched off when not in use. Remove the vented top plate of the generator and
connect into the terminal block as follows:
3 –phase 1-phase
3,4 -- 14 kW 3,4 / 4,7 / 6,0 / 7,7 kW
400 V - 415 V 230 V - 240 V
FACTORY SETTING Att. max. 7,7 kW
________________________________________________________________________________
3-phase
3,4 – 14 kW
230 V 3~
FACTORY SETTING
Used only in specific electrical systems-
to be ordered separately from the factory!
N
L1
L2
L3
L1
L2
L3
N
L1