Installation manual
Installation and servicing instructions strictly reserved for qualified gas installers
25
Open the installer connection side (2) to
carry out the electrical connections.
5.9.2 Connection to the PCB
30 mm max.
1
2
3
Legend
1 Terminal block
2 Electrical wires
3 Sheath
Warning ! When connecting electrical
cables to the terminal block on the PCB:
Keep a 30 mm maximum distance
between the terminal block (1) and the
stripped sheath (3).
Otherwise, fasten the electrical wires
(2) together with a cable tie.
Secure the cables with the electrical
box cable clamp.
5.9.3 Separation of high and low
voltage cables
2
3
1
Legend
1 Main board
2 Passage for high voltage
3 Passage for low voltage
•
•
•
•
Respect passage (2) for low voltage
cables and (3) for high voltage cables.
5.9.4 External controls connection
1
4
2
5
3
Legend
1 Neutral
2 Room Thermostat
3 Live
4 Frost Protection
5 Link wire
Important ! Remove link wire (5) when
fitting external controls.
•