Installation manual
Installation and servicing instructions strictly reserved for qualified gas installers
31
COD. 7 heating curve base
Choose a value:
15°C / 16°C / 17°C / 18°C / 19°C / 20°C / 21°C / 22°C / 23°C
/ 24°C / 25°C
COD. 8 burner forcing
Select an operating mode:
0 - normal operation. (factory setting)
1 - forcing at P. mini.
2 - forcing at P. maxi.
COD. 8 menus and following would only be used by After Sales Service Engineers.
COD. 23 select product code Select a value between 0 and 199.
COD. 24
set the offset on the
minimum fan speed
Select a value between 0 and 99 (99 = 990 rpm).
(no 10 rpm)
COD. 25
rmaximum
condensation power
Select a value between 0 and 99 (99 = -1485 rpm)
(no 15 rpm)
Heating curve
1
2
50
60
70
80
90
30
40
25
15
20
4.0
0.2
0.6
1.2
3.0
1.5
1.0
2.0
2.5
3.5
Legend
1 Menu 6 setting
2 Menu 7 setting
Outdoor temperature (°C)
Heating flow temperature (°C)