14.2 Removable plate / Silencer
Legend
1 Upper silencer
2 Upper silencer retaining screw
3 Lower silencer
4 Removable plate
14.2.1 Removable plate
Remove the removable plate (4) by
pulling towards you.
14.2.2 Silencer
Remove the removable plate (4).
Disconnect the lower silencer (3).
Remove the upper silencer retaining
screw (2).
Remove the upper silencer (1).
If necessary, clean the inside of the 2
silencers using a dry cloth taking care
not to damage the foam.
Repeat the above operations in reverse
to reassemble the unit.
14.3 Condensate trap
Legend
1 Condensate trap retaining clips
2 Condensate trap
3 Condensate outlet
4 Outlet siphon
Drain the filling siphon of the
condensate trap (see chapter on “Filling
the condensate trap”).
Disconnect the outlet pipe located
under the condensate trap (2).
Disconnect the condensate trap pipe
located under the combustion chamber
(see chapter on “Spare parts”).
Remove the condensate trap by
releasing the retaining clips (1) and
taking care not to spill any liquid.
Clean the pipes and remove any debris.
Clean the condensate trap by rinsing
under water.
Reassemble the unit taking care to
position the sealing gaskets correctly
and to fill the filling siphon according
to the chapter on “Filling of the