Installation manual

7
Instructions for Use
Push “MODE” to modify the operating
mode of the boiler. The green LED
indicates the selected mode.
Domestic hot water +
Timed central heating
Central heating and
domestic hot water
Domestic hot water only
Appliance frost protection
time Time setting
prog Heating program setting
8.4 Temperature adjustment
8.4.1 Domestic hot water temperature
adjustment
Push + or – on the side to change
domestic hot water temperature.
The ECO symbol remains until 49°C.
8.4.2 Heating temperature adjustment
Push + or – on the side to change
water temperature in the heating circuit.
Observation: a quick push on +/- or /
side displays the temperature value
previously selected.
8.5 Time setting
Press on the MODE key until the green
indicator is in the position in front of the
“time” mode.
The hour section starts flashing.
Use the + or – keys on the “time” side
to set present hour, then press MODE
key to validate.
The minute section starts flashing.
Use the + or – keys on the “time” side
to set minutes, then press MODE key to
validate.
8.6 Timed central heating setting
Press the MODE key until the green
indicator is in front of the “prog” mode.
Use the key on the “prog” side to
select on periods. A black square
appears on the display each time the
key is pressed.
Use the key on the “prog” side to
program off periods.
Each press on the and keys
corresponds to a 30 minute time period.
Press on the + and - keys on the “time”
side to move through the program
without modifying it.
Press on the MODE key to validate
your heating program.
8.7 «Boost» function
The “boost” function over rides the
program to advance the heating during
periods when the program is off. This
function remains active until the next new
period of heating is reached.
This function can only be activated in the
“Domestic hot water + timed
central heating” operating mode.
Press on the key on the “prog” side
for 5 seconds in order to activate the
“Boost” function.
The activated segments of the heating
program will then flash for 5 seconds.
Press on the key on the “prog” side
for 5 seconds to deactivate the “Boost”
function.