Technical information

12
1.4 Technical Data
All dimensions are given in millimetres (except
as noted).
See diagram 1.1 and Tables 1 and 2.
The data label is positioned on the inner door,
refer to diagram 1.2.
The Seasonal Efficiency Domestic Boilers UK
(SEDBUK) is: All HE boilers: Class ‘A’.
The value is used in the UK Government’s
Standard Assessment Procedure (SAP) for energy
rating of dwellings. The test data from which it has
been calculated has been certified by B.S.I.
TABLE 2
18 HE
BURNER %CO
2
Case Off 9.1 + 0.2 - 0.5
BURNER %CO
2
Case On 9.3 + 0.3 - 0.5
MIN. MAX.
APPROXIMATE m
3
/h 0.53 2.0
GAS RATE
(after 10 mins. ft
3
/h 18.7 70.06
from cold)
30 HE
BURNER %CO
2
Case Off 9.1 + 0.2 - 0.5
BURNER %CO
2
Case On 9.3 + 0.3 - 0.5
MIN. MAX.
APPROXIMATE m
3
/h 0.56 3.02
GAS RATE
(after 10 mins. ft
3
/h 19.8 107
from cold)
30 HE LPG
BURNER %CO
2
Case Off 10.5 + 0.3 - 0.7
BURNER %CO
2
Case On 10.7 + 0.3 - 0.7
MIN. MAX.
APPROXIMATE m
3
/h 0.56 3.02
GAS RATE
(after 10 mins. ft
3
/h 19.8 107
from cold)
Diagram 1.2
1.5 Condensate Drain
A plastic drain pipe must be fitted to allow discharge
of condensate to a drain.
Condensate should, if possible, be discharged
into the internal household draining system. If
this is not practical, discharge can be made
externally into the household drainage system or
a purpose designed soak away, see Section 7.3
for more detail.