Diagram 8.3
Diagram 8.6
12753
12750
Standard Top Rear flue - with the flue elbow
temporarily fitted, measure the distance from the
outside wall to the butt joint, see diagram 8.4. If
the measurement ‘Y’ exceeds 652mm , then the
appropriate length of extension pipe is required.
The minimum dimension is187mm (75mm min
wall thickness).
Telescopic Top Side flue - with the flue elbow
temporarily fitted, measure the distance from the
outside wall to the butt joint, see diagram 8.5. If
the measurement ‘Y’ exceeds 525mm, then the
appropriate length of extension pipe is required,
if the dimension is less than 320mm DO NOT cut
the flue, it can project to a maximum of 600mm,
if this is not desirable then a Standard flue MUST
be used and cut to length.
Diagram 8.4
12751
Standard Top Side flue - with the flue elbow
temporarily fitted, measure the distance from the
outside wall to the butt joint, see diagram 8.6. If
the measurement ‘Y’ exceeds 652mm, then the
appropriate length of extension pipe is required.
The minimum dimension is 270(Lhd) and 167(Rhd)
to suit a minimum wall thickness of 75mm.
Top rear flue - telescopic
Top rear flue - standard
Diagram 8.5
12752
Top side flue - telescopic
Top side flue - standard