Technical information
50
13.13 Heating Flow Thermistor
For access, refer to section 13.1.
Refer to diagram 13.7.
Remove the electrical connections from the
thermistor.
Remove the retaining clip from the flow pipe.
Remove the thermistor from the retaining clip.
NOTE: that the polarity of the wiring to thermistors
is unimportant.
13.14 Heating Return Thermistor
For access, refer to section 13.1.
Refer to diagram 13.7.
Remove the electrical connections from the
thermistor.
Remove the retaining clip from the flow pipe.
Remove the thermistor from the retaining clip.
NOTE: that the polarity of the wiring to thermistor
is unimportant.
13.15 Overheat Thermostat
For access, refer to section 13.1.
Refer to diagram 13.7.
Remove the electrical connections from the
overheat thermostat.
Remove the retaining clip from the flow pipe.
Remove the overheat stat from the retaining
clip.
NOTE: When fitting new thermostat, please ensure
that it is located correctly onto the flat area of the
pipe and the retaining clip is secure.
13.16 Condensate Drain
Refer to diagram 13.8.
Remove black flexible tubes from siphon
adapter.