Quick Reference Guide
Table Of Contents
- Contents
- About the Savi SMR-650-216 Mobile Reader
- Hardware Components
- Savi SMR-650-216 and Intermec CK61G Mobile Computer
- Reader Communication
- Docking and Charging the Intermec CK61G
- 1. Connect the AC power cord to the power supply.
- 2. Connect the power supply to the dock charger and plug it into an AC power outlet.
- 3. Unzip the two zippers that connect the lower section of the soft case to the upper section.
- 4. Unsnap the snaps that connect the lower section of the soft case to the upper section.
- 5. When the lower section of the soft case is free, fold it up out of the way of the Savi Boot Adapter on the bottom of the Intermec CK61G. The Intermec CK61G ships with a plastic NI (Non-Incendive) protection cover on the boot adapter connector.
- 6. Before docking the Intermec CK61G Mobile Computer, use a screwdriver to remove the plastic NI cover and store it in the pouch.
- 7. Insert the Intermec CK61G into the dock charger by sliding the molded slots on either side of the boot adapter onto the corresponding guides on the dock charger.
- 8. Press down until you feel the adapter engage the dock charger.
- Optional Charging Method Without the Docking Station
- Resetting the SMR-650-216
- Using the Intermec CK61G Mobile Computer
- Optimizing the SMR-650 Reader Tag Collection Range
- Optimal CK61G Mobile Device Battery Life
- 1. Turn on the mobile device.
- 2. Tap Start > Settings.
- 3. Select the System tab.
- 4. Tap Backlight.
- • Check Turn off backlight if device is not used for and select 5 min.
- • Uncheck Dim backlight if device is not used for 15 seconds.
- • Check Turn on backlight when a button is pressed or the screen is tapped.
- • Under Brightness Level, move the pointer to the midway point or less.
- • Uncheck Turn off backlight if device is not used for.
- • Uncheck Dim backlight if device is not used for 15 seconds.
- • Check Turn on backlight when a button is pressed or the screen is tapped.
- • Under Brightness Level, move the pointer to the midway point or less.
- • Under On All Power, check Restore backlight state on resume.
- • Under Automatic Backlight Control, select Turn Off In Bright Light.
- • Under Battery Power > Device turns off after =, select 5 minutes.
- • Under Battery Power > Screen turns off after =, select 5 minutes.
- • Under External Power > Device turns off after =, select Disabled.
- • Under External Power > Screen turns off after =, select Disabled.
- Contacting Savi Support Services
- Specifications
Savi SMR 650-216 Quick Reference Guide
18
Intermec CK61G Mobile Computer Keypad
Optimizing the SMR-650 Reader
Tag Collection Range
To optimize the Savi Mobile Reader SMR-650-216 tag collection range,
make sure the mobile device is perpendicular to your body. Hold it so the
reader is upright at approximately a 45° angle and you can easily see the
mobile device screen. With the Savi Mobile Reader SMR-650-216 in this
position, you can collect most tags within an omni-directional pattern of
200 feet (61m).