Appendix A
50 Savi Fixed Reader SR-650-101 Installation Guide
3. Type rssi? and press Enter to display the readers residual signal
strength indicator values.
4. Type diags and press Enter to record the MAC address, temperature,
and battery voltage.
To assign a new local IP address to the reader and modify gateway and
netmask addresses:
1. At the cursor, type localip=10.7.20.118 (or whatever valid IP address
you want to assign) and press Enter to set the reader IP address.
Figure A-12 Telnet local IP address display
2. Type reset and press Enter to cause the IP address to take effect.
Now you can use Telnet to connect to the reader at the new IP address.
3. Type gateway=10.100.4.1 (or whatever valid IP address you want to
assign) and press Enter to set the reader gateway IP address.
Figure A-13 Telnet Gateway IP address display
4. Type reset and press Enter to make the gateway IP address take effect.