SDS

metabolism. Ethanol administration is indicated in symptomatic patients or at blood methanol concentrations about
20ug/dl. Methanol is effectively removed by hemodialysis.
5. Fire Fighting Measures
Flash Point: -8 C (18 F)
LEL: N/A UEL: N/A
Extinguishing Media: Water fog, regular foam, carbon dioxide or dry chemical .
Fire/explosion: DANGER! EXTREMELY FLAMMABLE. Keep away from heat, sparks, flame and all other sources of
ignition. Do not smoke. Extinguish all flames and pilot lights, and turn off stoves, heaters, electric motors and all
other sources of ignition during use and until all vapors are gone. Beware of static electricity that may be generated.
May form carbon dioxide and carbon monoxide, various hydrocarbons.
Fire Fighting: Wear self-contained breathing apparatus with full face piece operated in pressure-demand or other
positive pressure mode. Straight water steam will spread fire. Use water spray to cool fire exposed containers and fire
affected zone until fire is out and danger of reignition has passed .
6. Accidental Release Measures
Methods/Materials for Containment and Cleaning Up:
Eliminate all ignition sources. Runoff may create fire or exposion hazard in sewer system. Absorb on fire retardant,
liquid-absorbing material. Shovel up and dispose of at an appropriate waste disposal facility in accordance with
current applicable laws and regulations, and product characteristics at time of disposal. Prevent spills from entering
storm sewers or drains and contact with soil.
Small spill: Wipe or scrap up any material. Wash area thoroughly with detergent and water; ventilate adequately with
good fresh air movement at floor level.
Large Spill: Wear proper protective equipment. Stop spill at source, dike area of spill to keep from spreading and
keep out of ground water and streams. Transfer material to metal containers. Absorb remainder with sand, clay,
earth, floor absorbent or other material and shovel into containers. Then wash area thoroughly with water and
detergent. Ventilate adequately wit good fresh air movement at floor level. Do not restart pilot lights or operate
electrical devices or other sources of sparks, flames or heat until all vapors (odors) are gone.
7. Handling and Storage
Do not breathe material. Keep container closed. Use only with adequate ventilation. Avoid contact with eyes, skin and
clothing. Containers of this material may be hazardous when emptied. Since emptied containers retain product
residues (vapor and liquid), all hazard precautions given in the data sheet must be observed. All five-gallon pails and
larger metal containers should be grounded and/or bonded when material is transferrred.
Store in cool place, out of hot sun. All containers are subject to damage in storage and transit . Damaged containers
may start leaking immediately or at a later time. Do not store flammable materials in areas with widely fluctuating
temperatures and do not store where vapors may come in contact with flames, sparks, or heat. Flammable mateials
should not be stored in below ground areas that cannot be adequately ventilated at floor level. Do not use cutting or
welding torches near full or empty containers. Closed containers may expode if exposed to extreme heat. Never use
internal gas or air pressure to remove contents from a container. Emptied containers may retain product residues (e.g.
vapor and liquid or solids); Therefore all precautions given in this sheet must be observed until a container is
thoroughly cleaned or destroyed. All containers must be completely drained, (less than one inch of material in the
bottom of 55 gallon container) before disposal. If possible emptied container of 55 gallons or more should be given to
reconditioner for cleaning.
8. Exposure Controls/Personal Protection
Other Exposure LimitsACGIH Exposure LimitsOSHA Exposure LimitsChemical Name / CAS No.
TOLUENE
108-88-3
20 ppm TWA, A4
200 ppm TWA
300 ppm Ceiling
Not Established
SDS for: 230N
Page 3 of 7
Printed: 4/1/2021 at 2:29:16PM