Use And Care Manual

21
Installation Instructions
a. Hand Assembly:
1. Make certain the tank valve and all the appliance valves are in the “OFF” position.
2. When connecting the regulator/burner valve assembly to the tank valve,
turn the large plastic nut clockwise until it stops.
3.Gas will not flow unless the plastic nut is completely connected.
4. HAND TIGHTEN ONLY.
b. Hand Disassembly:
1.Make certain the tank valve and all the appliance valves are in the “OFF” position.
2.Turn the large plastic nut counter-clockwise until it is disassembled.
3. HAND LOOSEN ONLY.
c. Excess Flow Control
To ensure this does not cause difculty in lighting the grill,follow these
instructions:
1. Make sure all burner valves are “OFF.
2. Open the tank valve and wait 5 seconds.
d.Temperature-Activated Shut-Off
The large plastic nut on the regulator assembly is designed in coordination
with a check valve in the tank valve to shut off the ow of gas when exposed
to temperatures between 240-300° F In the event of a re or hose break,
one of the safeguards will function to control or stop the flow of gas from the
propane tank.Never attempt to use damaged equipment.
IMPORTANT:Before the use of a fresh tank of gas,please check leakage
around the connections according to section Checking Gas Leakson
page and make sure there is no leakage or vapor accumulation in the 28
cabinet.Make sure all openings around side walls are not blocked.
IMPORTANT:Place dust cap on cylinder valve outlet whenever the cylinder
is not in use.Only install the type of dust cap on the cylinder valve outlet
that is provided with the cylinder valve.Other types of caps or plugs may
result in leakage of propane.
1
示:在使28
b卸:
5
明:
1
25
240 - 300°F裂,
使
2
1
2阀/燃
3.
3.
dTemperature-Activated
c.
4
示:当使
The propane regulator assembly incorporates an excess flow device designed
to supply the grill with sufcient gas ow under normal conditions yet control
excess gas flow.
Rapid changes in pressure can trigger the excess flow device providing a low
ame and low temperature.If the tank valve is turned open to allow gas ow
while a burner valve is open,the surge of pressure will cause the device to
activate.The device will remain closed until the pressure is equalized.This
should occur within 5 seconds.