Use And Care Manual

22
Installation Instructions
Gas Requirements
The grill is set and tested at the factory for use with LP-Gas only.
LP Gas
LP GAS System
LP
Gas Consumption
The regulator supplied is set for 11 in.water column (WC)and is for use with
LP gas only.
The factory-supplied regulator and hose must be used with a 20 lb. LP gas tank.
Contact your gas supplier for a special regulator for bulk gas that fuels
other appliances
Total gas consumption of this grill with the burner(s) on “HIGH” Table 1 below.
Burner Type
Main Burners
Side Burner
BTU/Hr
36,000
12,000
Locating the Grill
This gas appliance is designed and certied for outdoor use only.Do not
operate the grill inside a building,garage,recreation vehicle,screened porch
or any enclosed area.Keep the grill away from windy areas,but keep the grill
in a well-ventilated area.Do not obstruct the flow of combustion and ventilation
air around the grill.
Warning:Do not place the grill under overhead,unprotected combustible
surfaces.
Clearance to Combustible Construction
A minimum clearance of 36 in.from the sides of the grill and a minimum
clearance of 36 in. from the back of the grill to adjacent vertical combustible
constructions must be maintained.However,the manufacturer strongly
suggests a 6 ft.clearance of the grill to combustible constructions.
Clearance to Noncombustible Construction
A minimum clearance of 36 in.from the back of the grill above the cooking
surface to noncombustible constructions is required to allow the grill hood
to open completely.A minimum of 36 in.clearance to the sides of the grill
above the cooking surface to noncombustible constructions is recommended.
The grill can be installed directly next to noncombustible construction below
the cooking surface.