Use And Care Manual
4
Only a 20 lb.LP-gas cylinder is allowed.The cylinder
must be constructed and marked in accordance
with the Specifications for LP Gas Cylinders of
the U.S.Department of Transportation(D.O.T.)
or the National Standard of Canada,
CAN/CSA-B339,Cylinders,Spheres and Tubes
for Transportation of Dangerous Goods; and
Commission.Dimensions for a 20 lb. LP-Gas
cylinder are:
●
●
Never use the grill without the drip tray installed and hung under the
burner box.Without the drip tray,hot grease and debris could leak
downward and produce a fire hazard.
Use only the gas pressure regulator supplied with this appliance.This
regulator is set for an outlet pressure of 11.0 wc.
●
●
The cylinder used must include a collar to protect the cylinder valve.
Do not store a spare LP-gas cylinder under or near this appliance.
●
Never fill the cylinder beyond 80 percent full.
●
The regulator and hose assembly must be routed through the left leg
assembly.Regulator must be locked with regulator hose lock before
connect with LP tank.See page for detailed assembly instructions.18
●
DANGER: If the information in above is not followed exactly,a fire
causing death or serious injury may occur.
●
The outdoor cooking gas appliance must be isolated from the gas
supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply system at test pressures
equal to or less than 1/2 PSI (3.5 KPa).
●
CALIFORNIA PROPOSITION 65 WARNING: The burning of gas cooking
fuel generates some byproducts which are on the list of substances known
by the State of California to cause cancer,reproductive harm,or other birth
defects.To reduce exposure to these substances,always operate this unit
according to the use and care manual,ensuring you provide good ventilation
when cooking with gas.
●
SAFETY INFORMATION
Fig.1
8 in.
13.9 in.
12.2 in.
18 in.
只有一个20磅的液化石油气钢瓶是允许的。气瓶必须按照美国LP气体
气瓶的规格建造和标记交通部(D.O.T.)或加拿大国家标准CAN/ sa - b339,
危险品运输用钢瓶、球体、管;andCommission。20磅lp -气瓶的尺寸为:
不要在有风的地方使用烤架。
如果没有安装和悬挂在燃烧器箱下的滴油盘,切勿使用烤架。
如果没有滴漏盘,热油脂和碎片可能会向下渗漏,并产生火灾隐患。
仅使用该设备提供的气体压力调节器。
该调节器设置为出口压力为11.0 wc。
所使用的气缸必须包括一个护套以保护气缸阀门。
不要将备用的液化石油气气瓶储存在设备下方或附近。
不要把气瓶装满超过80%。
调节阀和软管总成必须通过左腿总成。
在连接LP水箱之前,调节阀必须用调节阀软管锁紧固。
详细的组装说明请参阅第18页。
危险:以上信息不准确,可能发生火灾,造成人员死亡或重伤。
加州65号提案警告:燃烧燃气烹饪燃料会产生一些副产品,
这些副产品列在加州已知会导致癌症、生殖伤害或其他出
生缺陷的物质清单上。为了减少接触这些物质,请始终按
照使用和护理手册操作本设备,确保在使用气体烹饪时提供良好的通风。
在燃气供应系统的任何压力测试中,在测试压力等于或小于
1/2 PSI (3.5 KPa)的情况下,必须通过关闭其单独的手动关闭阀,
将室外烹饪用燃气器具与燃气供应管道系统隔离。