User manual

Scaleart OHG Schillerstraße 3 D-67165 Waldsee
Quick฀reference฀manual฀
page฀12
Functional฀Overview฀Receiver฀ScaleART฀Commander
BEC:
The฀ScaleART฀Commander฀receiver฀CM-1000฀and฀CM-5000฀is฀equiped฀with฀an฀internal฀BEC฀system฀for฀its฀own฀power฀supply.฀This฀
system฀is฀active฀as฀soon฀as฀an฀external฀supply฀tension฀of฀6-18V฀is฀applied.฀However,฀this฀BEC฀system฀only฀serves฀for฀the฀internal฀
power฀supply฀of฀the฀receiver.
You฀ need฀ another฀ additional฀ external฀ BEC฀ system฀ for฀ the฀ power฀ supply฀ of฀ the฀ servo. Depending฀ on฀ how฀ many฀ servos฀are฀
connected,you฀can฀either฀use฀the฀BEC฀which฀is฀used฀in฀most฀cruise฀control฀or฀you฀may฀use฀a฀separate฀BEC฀system.฀When฀using฀
a฀separate฀BEC฀system,฀it฀is฀in฀most฀cases฀recommended฀to฀remove฀the฀red฀+฀cable฀from฀the฀servo฀plug฀of฀the฀cruise฀control.
It฀is฀also฀possible฀to฀operate฀the฀Commander฀receivers฀without฀an฀external฀power฀supply฀Then฀the฀receiver฀is฀automatically฀
supplied฀via฀the฀servo฀BEC฀system.฀However,฀a฀battery฀monitoring฀is฀not฀given.
Receiver
Commander CM-1000
Commander CM-5000
Servo slots
10
16
Usable for switching functions
10
16
Usable as input
-
8 (No 9-16)
Functional modules (mixer)
8
16
Control light bus
Optional
Yes
IT output
-
Compatible with Robbe and Scaleart
Integrated controller for auxiliary or
main drives
-
Up to 3 amperes, with excess current, short
circuit and temperature protection
Control of multiswitch modules
1 compatible with Graupner, Robbe and
Scaleart
8 compatible with Graupner, Robbe and
Scaleart
Measurement battery tension
Yes
Measurement input current
No
Yes
Battery management with reverse
voltage protection
No
Loadable with up to 12 amperes, operating
voltage maximum 18 volts
Additional sensor ports
-
2
Inclinometer
No
Inclination and pitch
Adjustable alarm thresholds
Battery tension
Individual minimum and maximum values
for all measured values
Hydraulic pump control
Monitors max. 16 functions
Monitors max. 32 functions
Mixer for tracked vehicles
Yes
Limit switch via positions sensor
No
Yes
Undervoltage-stop
Yes
Controller current limiter
No
Yes
Sequential gearbox control
up to 3 gears
up to 4 gears
Free path template
Yes
Brake light function
Yes
Smoke generator control
No
Yes
Resettable operating hour counter
1
4
Adjustable servo manipulating time
0 - 20 seconds
0 - 20 seconds
Adjustable servo paths
0- 200% right and left separated
0- 200% right and left separated
Hydraulic simulation for servos
Yes
Programmable process sequence
control
No
Yes
Password protection
Separated for operation and configuration
Power supply
BEC or drive battery, from 4.8 to 18 volts
Bus-compatible (several interpreters
in the model)
Yes
Software update in the model is
possible
Yes