Owner`s manual

21
Replacement part list:
Caution: Use only original SCAN replacement parts. Do not use substitute materials.
Article Article #
Glass for SCAN 5-2 57055011
Smoke deflector cassette for SCAN 5-2 54999009 05091
Single baffle plate for SCAN 5-2 54050000 091
Set fire bricks for and SCAN 5-2 53050000 091
Gaskets (packets):
Door seal (Packet no. 4) 55100004
Glass seal (Packet no. 3 x 2 pieces) 55100003
Ash Tray (Packet no. 5) 55100005
Scan 5-2 door 56055010
Creosote Formation and the Need for Removal:
When wood is burned slowly it produces tar and other organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow
burning fire. As a result, creosote residue accumulates in the flue lining. When ignited this creosote
makes an extremely hot fire.
The chimney connector and chimney should be inspected at least twice monthly during the heating
season to determine if a creosote buildup has occurred. If creosote has accumulated it should be
removed to reduce the risk of a chimney fire.
Door Glass:
A commercial glass cleaner designed for stoves is recommended for cleaning the glass. The glass
can also be cleaned as follows: Dip a moist cloth or old newspaper in the ashes and use this to clean
the glass. Attention: The ashes should not get into contact with your skin! Wipe with a dry cloth. The
ceramic door packing cord must not get wet.
Be careful not to abuse the glass by striking or slamming the door shut.
Do not operate the stove with broken glass. If the glass breaks then replace it promptly.
Use only replacement packing cord listed for the door, glass and ash drawer.