Technical data

ASSEMBLY
15
Connecting piece top outlet
Your wood-burning stove has been prepared for a top outlet by the
manufacturer. Remove the cover plate from the top plate, and fit the
connecting piece, the enclosed seal, and the fittings from the service
package. At the same time, fix the safety fitting crosswise to prevent
damage to the baffle plate when sweeping the chimney.
Connecting
piece
Safety
fitting
B
B
Bracket
Seal for
connecting
piece
Screws for
adjusting
the height
of the top
plate
Screws for adju-
sting the height
of the frame for
the top plate
The Scan 58 with "see through" plinth
External combustion air can be connected underneath the combu-
stion chamber using the connection piece supplied and connecting
outdoor air.
If you decide on connecting external combustion air through the
bottom of the plinth, unscrew the blanking plate and fit it under the
combustion chamber. Then fit the connection piece supplied under
the plinth as shown below before connecting outdoor air.
Scan 58-7 and Scan 58-8
External combustion air can be connected in the magazine under the
combustion chamber by fitting the connection piece and fresh air
box supplied. Outdoor air can then be connected through the bottom
or rear of the stove.
Scan 58 Wall-hung model