Tus neeg siv phau ntawv

If the length of the cable is not enough, it should be replaced by a qualified person. Do not use an
extension cord.
OPERATION
Carel controller
The operation of the equipment is totally controlled by
the digital thermostat, which allows for the selection of
temperature and controls the operation of the lighting
using the button.
Connect the equipment to the mains. If "OFF" appears
in the digital display, press the ON/OFF button for 3
seconds.
The factory set point in positive refrigerated equipment is +3°C, and can be set on the thermostat
between + 1˚C and + 10˚C.
In the negative cold models, the factory set point is -20˚C, and can be adjusted in the thermostat
between -16˚C to -22˚C.
In sub-zero models, the factory set point is -2˚C, and can be adjusted between -3˚C and + 10˚C.
Operating Message
Message
Description
E0
Ambient Probe Failure
E1
Defrost Probe Failure
L0
Low Temperature Alarm
HI
High Temperature Alarm
DF
Defrosting in progress
OFF
Standby
Door
Open Door
ENS
Energy Saving Mode
To switch off, press the ON/OFF button (information "OFF" on the display, equipment off) or
disconnect the plug from the mains. Wait 10 minutes before turning the equipment back on.
Product Loading
Load the products in the equipment ensuring they are properly packed, avoiding accidents when
handling.