Tus neeg siv phau ntawv
Repair Guide:
Internal fan does not work
Temperature below the limits
LED lights do not light up
Light does not turn off
Led light flashing
Does not reach the temperature, but stops and starts
Suction line ice
It is cold, it does not reach the temperature
•
Fan wires off /Check connection
•
•
Incorrect wire in the thermostat
•
•
•
Door open (door open alarm/ close the door and see door micro connection)
•
•
Faulty fan/ Replace fan
•
Faulty Digital thermostat relay/ Replace digital thermostat
•
Temperature of evaporator above 10ºC, fan off/ Wait for equipment to cool down
•
Fan stuck/ Check fan position
•
22
Set Point temperature / Check settings
•
Wrong thermostat connections / Check connections
•
2
Safety thermostat/ See position
•
•
Glass door Thermostat/ Press AUX
•
•
Opaque door/ Close door open door
•
•
Incorrect transformer wires/ Check Connections
•
•
Faulty transformer/ Replace transformer
•
•
Faulty Led lights / Replace led lights
Too much gas/Check gas charge
If the malfunction continues after these checks, technical assistance should be requested from your
authorized dealer.
Please indicate the type of malfunction, type of appliance, serial number, and date of purchase
(invoice). The serial number and type of appliance are described on the equipment information
label (normally located inside the equipment, on the side).
In case of need for accessories or spare parts, you should also request them from your authorized
dealer, always mentioning the equipment data described above.
Note: For the protection of persons and property against direct/ indirect contacts, the use of a
differential protection of the power outlet directly to this equipment with a trip sensitivity of 300
mA is mandatory.
Possible cause / repairs