User Manual

Table Of Contents
©
Scania CV AB 2013, Sweden
CAN interface for bodywork
Detailed description of CAN messages
11:90-01 Issue 1 en-GB 104 (139)
Supply Pressure
Identifier: 18 FE AE 30
Transmission interval: 1,000 ms
Always sent from BWS.
Byte Bit Length Explanation State Resolution Limits Note
118Pneumatic supply pressure 8 kPa/bit 0 to 2 000 kPa
Error FEh
Not available FFh
218Parking and/or trailer air pressure 8 kPa/bit 0 to 2 000 kPa
Error FEh
Not available FFh
318Service brake air pressure, circuit 1 8 kPa/bit 0 to 2 000 kPa
Error FEh
Not available FFh
418Service brake air pressure, circuit 2 8 kPa/bit 0 to 2 000 kPa
Error FEh
Not available FFh
5..6 Not used
7..8 Not defined
712Air compressor status
Compressor not active 00
Compressor active 01
Error 10
Not available 11
3 6 Not defined