User Manual

Table Of Contents
©
Scania CV AB 2013, Sweden
CAN interface for bodywork
Detailed description of CAN messages
11:90-01 Issue 1 en-GB 120 (139)
Less than 1 minute 0000
One minute 0001
Two minutes 0010
Three minutes 0011
Four minutes 0100
Five minutes 0101
Six minutes 0110
Seven minutes 0111
Eight minutes 1000
Nine minutes 1001
Ten minutes 1010
Eleven minutes 1011
Twelve minutes 1100
Thirteen minutes 1101
Error 1110
Not available 1111
54Transmission oil level measurement 16 states/4 bit, 0
offset
0 - 15
Cndtns vld fr trns ol lvl measurement 0000
Cndtns nt vld stt ing tmr stll cntng dw 0001
Conditions not valid trans in gear 0010
Cndtns nt vld trans fluid temp too low 0011
Cndtns nt vld trns fluid temp too high 0100
Cndtns nt vld vhcl mvng otpt shft spd t 0101
Cndtions not valid vehicle not level 0110
Cnditions not valid eng speed too low 0111
Byte Bit Length Explanation State Resolution Limits Note